Integrated Silicon Pressure Sensor

No Preview Available !

MPXV7007DP pdf
Freescale Semiconductor
+ Integrated Silicon Pressure Sensor
On-Chip Signal Conditioned,
Temperature Compensated and
Calibrated
The MPXV7007 series piezoresistive transducers are state-of-the-art
monolithic silicon pressure sensors designed for a wide range of applications,
but particularly those employing a microcontroller or microprocessor with A/D
inputs. This transducer combines advanced micromachining techniques, thin-
film metallization, and bipolar processing to provide an accurate, high level
analog output signal that is proportional to the applied pressure.
Features
• 5.0% Maximum Error Over 0° to 85°C
• Ideally Suited for Microprocessor or Microcontroller-Based Systems
• Temperature Compensated Over –40° to +125°C
• Thermoplastic (PPS) Surface Mount Package
• Patented Silicon Shear Stress Strain Gauge
• Available in Differential and Gauge Configurations
Pressure
MPXV7007
Rev 1, 1/2009
MPXV7007
Series
-7 to 7 kPa (-1 to 1 psi)
0.5 to 4.5 V Output
Application Examples
• Hospital Beds
• HVAC
• Respiratory Systems
• Process Control
Device Name
Small Outline Package
MPXV7007GC6U
MPXV7007GC6T1
MPXV7007GP
MPXV7007DP
MPXV7007G6T1
MPXV7007G6U
Package
Options
Rails
Tape & Reel
Trays
Trays
Tape & Reel
Rails
Case
No.
ORDERING INFORMATION
# of Ports
Pressure Type
None Single Dual Gauge Differential Absolute
Device
Marking
482A
482A
1369
1351
482
482
••
••
••
••
••
MPXV7007G
MPXV7007G
MPXV7007GP
MPXV7007DP
MPXV7007G
MPXV7007G
SMALL OUTLINE PACKAGE
MPXV7007G6T1/U
CASE 482-01
MPXV7007GC6U/C6T1
CASE 482A-01
MPXV7007GP
CASE 1369-01
MPXV7007DP
CASE 1351-01
© Freescale Semiconductor, Inc., 2005, 2009. All rights reserved.


Freescale Semiconductor Electronic Components Datasheet

MPXV7007DP Datasheet

Integrated Silicon Pressure Sensor

No Preview Available !

MPXV7007DP pdf
Pressure
Operating Characteristics
Table 1. Operating Characteristics (VS = 5.0 Vdc, TA = 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
Figure 3 required to meet specification.)
Characteristic
Symbol Min Typ Max Unit
Pressure Range(1)
POP
-7
7 kPa
Supply Voltage(2)
VS 4.75 5.0 5.25 Vdc
Supply Current
Minimum Pressure Offset(3)
@ VS = 5.0 Volts
Full Scale Output(4)
@ VS = 5.0 Volts
Full Scale Span(5)
@ VS = 5.0 Volts
Accuracy(6)
(0 to 85°C)
(0 to 85°C)
(0 to 85°C)
(0 to 85°C)
Io — 7.0 10 mAdc
Voff 0.33 0.5 0.67 Vdc
VFSO
4.3
4.5
4.7
Vdc
VFSS
4.0
— Vdc
±5.0
%VFSS
Sensitivity
V/P — 286 —- mV/kPa
Response Time(7)
tR — 1.0 —- ms
Output Source Current at Full Scale Output
Warm-Up Time(8)
IO+ — 0.1 —- mAdc
— — 20 —- ms
Offset Stability(9)
± 0.5
—- %VFSS
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range.
3. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
4. Full Scale Output (VFSO) is defined as the output voltage at the maximum or full rated pressure.
5. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
6. Accuracy (error budget) consists of the following:
Linearity:
Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25°C.
TcSpan:
Output deviation over the temperature range of 0° to 85°C, relative to 25°C.
TcOffset:
Output deviation with minimum rated pressure applied, over the temperature range of 0° to 85°C, relative to
25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C.
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
8. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
9. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
MPXV7007
2
Sensors
Freescale Semiconductor


Part Number MPXV7007DP
Description Integrated Silicon Pressure Sensor
Maker Freescale Semiconductor
Total Page 10 Pages
PDF Download
MPXV7007DP pdf
Download PDF File
[partsNo] view html
View PDF for Mobile






Related Datasheet

1 MPXV7007DP Integrated Silicon Pressure Sensor Freescale Semiconductor
Freescale Semiconductor
MPXV7007DP pdf






Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

site map

webmaste! click here

contact us

Buy Components