DRV421 Integrated Magnetic Fluxgate Sensor for Closed-Loop Current Sensing
1 Features
•1 High-Precision Integrated Fluxgate Sensor – Offset and Drift: ±8 µT max, ±5 nT/°C typ
• Extended Current Measurement Range – H-Bridge Output Drive: ±250 mA typ at 5 V
• Precision Shunt Sense Amplifier – Offset and Drift (max): ±75 µV, ±2 µV/°C – Gain Error and Drift (max): ±0.3%, ±5 ppm/°C
• Precision Reference – Accuracy and Drift (max): ±2%, ±50 ppm/°C – Pin-Selectable Voltage: 2.5 V or 1.65 V – Selectable Ratiometric Mode: VDD / 2
• Magnetic Core Degaussing Feature • Diagnostic Features: Overrange and Error Flags • Supply Voltage Range: 3.