Data Sheet
FEATURES
Complete supervisory and sequencing solution for up to 8 supplies
8 supply fault detectors enable supervision of supplies to <0.5% accuracy at all voltages at 25°C <1.0% accuracy across all voltages and temperatures
4 selectable input attenuators allow supervision of supplies to 14.4 V on VH 6 V on VP1 to VP3 (VPx)
4 dual-function inputs, VX1 to VX4 (VXx) High impedance input to supply fault detector with thresholds between 0.573 V and 1.