• Part: ADXL1002
  • Description: High Frequency MEMS Accelerometers
  • Manufacturer: Analog Devices
  • Size: 1.29 MB
ADXL1002 Datasheet (PDF) Download
Analog Devices
ADXL1002

Description

The ADXL1001/ADXL1002 deliver ultralow noise density over an extended frequency range with two full-scale range options, and are optimized for industrial condition monitoring. The ADXL1001 (±100 g) and the ADXL1002 (±50 g) have typical noise densities of 30 µg/√Hz and 25 µg/√Hz, respectively.

Key Features

  • Single in plane axis accelerometer with analog output
  • Linear frequency response range from dc to 11 kHz (3 dB point)
  • Resonant frequency of 21 kHz
  • Ultralow noise density
  • 30 µg/√Hz in ±100 g range (ADXL1001)
  • 25 µg/√Hz in ±50 g range (ADXL1002)
  • Overrange sensing plus dc coupling allows fast recovery time
  • Sensitivity performance
  • Sensitivity stability over temperature 5%
  • Linearity to ±0.1% of full-scale range