Datasheet Summary
DUAL FORWARD-CONDUCTING P-GATE THYRISTOR PROGRAMMABLE OVERVOLTAGE PROTECTOR
TISP61089HDM Overvoltage Protector
Intended for Use in GR-1089-CORE Issue 3 pliant Line Cards
Dual, Voltage-Programmable SLIC Protector
- Low 15 mA max. Gate Triggering Current
- Supports Battery Voltages Down to -155 V
- High 150 mA min. Holding Current
Rated for GR-1089-CORE Issue 3 Conditions
Impulse Waveshape 2/10
10/1000
GR-1089-CORE Test
Section Test #
1, 3
IPPSM A 500
Meets GR-1089-CORE First Level A.C. Power Fault Conditions
GR-1089-CORE Section 4.6.10
Test # 1 2 3 4 6 7 8 9
I RMS
0.33 0.17
1 1 0.5 2.2 3 5
Power Fault Duration s
900...