SERIES: CBM-50V DESCRIPTION: DC BLOWER
FEATURES
• omniCOOLTM bearing system
• multiple speed options for different cooling needs
• 50 x 50 mm frame
• auto restart protection standard on all models
date 02/07/2020
page 1 of 7
MODEL
input
voltage
rated
(Vdc)
range
(Vdc)
input
current1
max
(mA)
input
power1
max
(W)
CBM-5015V-130
12 6~13.8 40
0.48
CBM-5015V-140
12 4.5~13.8 65
0.78
CBM-5015V-150
12
4.5~13.8
115
1.38
CBM-5015V-160
12
4.5~13.8
196
2.36
CBM-5020V-144
12 6~13.8 88
1.1
CBM-5020V-148
12
6~13.8
104
1.3
CBM-5020V-152
12
6~13.8
124
1.5
Notes:
1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
5. Typical rated speed is measured as RPM±10% at rated voltage.
6. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
rated
speed1
typ
(RPM±15%)
3000
4000
5000
6000
44005
48005
52005
air
flow2
(CFM)
2.6
3.5
4.5
5.4
4.8
5.2
5.7
static
pressure3
(inch H2O)
0.18
0.40
0.67
0.97
0.46
0.56
0.66
noise4
max
(dBA)
23.4
33.1
39.8
42.2
30.0
33.0
35.0
cuidevices.com




CUI

CBM-5015V-130 Datasheet Preview

CBM-5015V-130 Datasheet

DC BLOWER

No Preview Available !

Additional Resources: Product Page | 3D Model
CUI Devices SERIES: CBM-50V DESCRIPTION: DC BLOWER
date 02/07/2020 page 2 of 7
INPUT
parameter
conditions/description
min
operating input voltage1
4.5
starting voltage2
Note:
1. See Model section on page 1 for specific input voltage ranges.
2. Starting voltage for models CBM-5015V-130, CBM-5020V-144, CBM-5020V-148, and CBM-5020V-152 is 6 Vdc.
PERFORMANCE3
parameter
conditions/description
rated speed
at rated voltage, 25°C, after 10 minutes
air flow
static pressure
at 0 inch H2O, see performance curves
at 0 CFM, see performance curves
noise
at 1 m
Note:
3. See Model section on page 1 for specific values.
min
3000
2.6
0.18
23.4
PROTECTIONS
parameter
auto restart
conditions/description
when the fan motor is locked by an external force,
the device will temporarily turn off electrical power
to the motor and restart automatically when the
locked rotor condition is released
min
SAFETY & COMPLIANCE
parameter
insulation resistance of frame
dielectric strength
safety approvals
EMI/EMC
life expectancy
RoHS
conditions/description
at 500 Vdc between internal stator and positive
lead wire
apply 500 Vac for 1 minute between housing and
positive lead wire
UL/cUL 507, TUV (EN 60950-1)
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
at 40°C, 65% RH
yes
min
10
ENVIRONMENTAL
parameter
operating temperature
storage temperature
conditions/description
min
-10
-40
typ
12
4.5
typ
typ
typ
70,000
typ
max
13.8
units
Vdc
Vdc
max
6000
5.7
0.97
42.2
units
RPM
CFM
inch H2O
dBA
max
units
max
units
MΩ
hours
max
70
70
units
°C
°C
cuidevices.com


Part Number CBM-5015V-130
Description DC BLOWER
Maker CUI
PDF Download

CBM-5015V-130 Datasheet PDF






Similar Datasheet

1 CBM-5015V-130 DC BLOWER
CUI





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy