Additional Resources: Product Page | 3D Model
CUI Devices │ SERIES: CBM-60V │ DESCRIPTION: DC BLOWER
date 02/07/2020 │ page 2 of 6
INPUT
parameter
operating input voltage
starting voltage
conditions/description
PERFORMANCE1
parameter
conditions/description
rated speed
at rated voltage, 25°C, after 10 minutes
air flow
static pressure
at 0 inch H2O, see performance curves
at 0 CFM, see performance curves
noise
at 1 m
Note:
1. See Model section on page 1 for specific values.
PROTECTIONS
parameter
auto restart
conditions/description
when the fan motor is locked by an external force,
the device will temporarily turn off electrical power
to the motor and restart automatically when the
locked rotor condition is released
SAFETY & COMPLIANCE
parameter
insulation resistance of frame
dielectric strength
safety approvals
EMI/EMC
life expectancy
RoHS
conditions/description
at 500 Vdc between internal stator and positive
lead wire
apply 500 Vac for 1 minute between housing and
positive lead wire
UL/cUL 507, TUV (EN 60950-1)
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
at 40°C, 65% RH
yes
ENVIRONMENTAL
parameter
operating temperature
conditions/description
storage temperature
min
4.5
min
3400
3.9
0.19
28.8
min
min
10
min
-10
-40
typ
12
4.5
typ
typ
typ
70,000
typ
max
13.8
units
Vdc
Vdc
max
5000
5.7
0.44
40.2
units
RPM
CFM
inch H2O
dBA
max
units
max
units
MΩ
hours
max
70
70
units
°C
°C
cuidevices.com