Current Monitoring System

No Preview Available !

Installation / Monitoring Technique
varimeter
Current Monitoring System
IK 9138, IK 9139
According to IEC/EN 60 255, DIN VDE 0435-303
Modular system, extension possible
For measuring currents of 0.175 to 16 A
Small amount of wiring required
Compact design
LED display
Width 17.5 mm
Function Diagram
Approvals and Marking
I
I
Response value
Application
UH
IK 9138
IK 9138
IK 9139
LED I<
on
off
11-14
IK 9138
11-12
t
t
M6910_a
P
For monitoring the current consumption levels of different
electricity consumers
For identifying cable breakages and burned-out heating
cartridges
Function
The IK 9138 / IK 9139 varimeter is a modular current monitoring system
that consists of a reporting unit IK 9138 and 1 to 30 current monitors IK
9139.This means that the current consumption levels of different electricity
consumers can be monitored. If one of the currents that is being monitored
drops below the fixed current setting, the LEDs on the relevant current
monitor and the reporting unit go on. The central reporting relay in the
reporting unit is actuated. The reporting unit needs to be connected to an
auxiliary voltage supply. The current monitors obtain their supply voltage
from the reporting unit via a plug-in bus line.
Circuit Diagrams
A1
11 24
A1 A2
12
11 14
23 24
14 23
12 A2
M7503_b
IK 9138.20
i
k
i I< k
IK 9139
M7504_b
Indicator
LED:
Technical Data
Input
on, when the current drops below the
setting
Auxiliary voltage
Voltage range
UH:
at < 10% residual ripple:
at 10 ... 48% residual ripple:
Nominal consumption:
Current consumption:
Nominal frequency:
Frequency range:
Switching point (fixed):
AC/DC 24 V
AC 0.8 ... 1.1 UH
DC
DC
0.5
0.9 ...
0.8 ...
W+n
11x..210.UU45HH
W
(n = number of IK 9139)
15 mA + n x 15 mA via IK 9138
50 Hz
±5%
Switching
points
(available)*
Maximum
overload,
permanent
Maximum
overload, 2 s
0.175 A
5 A 7.5 A
0.75 A
20 A
150 A
1 A 20 A 150 A
5 A 20 A 150 A
10 A
40 A
150 A
16 A
40 A
150 A
* Other switching points possible on request
Hysteresis:
< 10 %
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
1
IK 9138, IK 9139 / 21.05.03 e




DOLD

IK9138 Datasheet Preview

IK9138 Datasheet

Current Monitoring System

No Preview Available !

Technical Data
Output
Contacts
IK 9138.20:
1 changeover contact, 1 NO contact
TShweitrcmhainl gcucrarpenact iItthy:
5A
to AC 15
NO contact:
3 A / AC 230 V IEC/EN 60 947-5-1
NC contact:
1 A / AC 230 V IEC/EN 60 947-5-1
Electrical life
IEC/EN 60 947-5-1
to AC 15 at 3 A, AC 230 V: 5 x 105 switching cycles
Short circuit strength
max. fuse rating:
6 A gL
IEC/EN 60 947-5-1
Mechanical life:
20 x 106 switching cycles
General Data
Operating mode:
Temperature range:
Clearance and creepage
distances
rated impuls voltage/
pollution degree
Input/output:
EMC
Electrostatic discharge:
HF irradiation:
Fast transients:
Surge voltages
between
wires for power supply:
between wire and ground:
Interference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire connection:
Wire fixing:
Mounting:
Weight
IK 9138:
IK 9139:
Continuous operation
- 20 ... + 60°C
4 kV / 2
8 kV (air)
10 V/m
2 kV
IEC 60 664-1
IEC/EN 61 000-4-2
IEC/EN 61 000-4-3
IEC/EN 61 000-4-4
1 kV
IEC/EN 61 000-4-5
2 kV
IEC/EN 61 000-4-5
Limit value class B
EN 55 011
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0.35 mm
frequency 10 ... 55 Hz IEC/EN 60 068-2-6
20 / 060 / 04
IEC/EN 60 068-1
EN 50 005
2 x 2.5 mm2 solid or
2 x 1.5 mm2 stranded ferruled
DIN 46 228-1/-2/-3/-4
Flat terminals with self-lifting
clamping piece
IEC/EN 60 999-1
DIN rail
IEC/EN 60 715
70 g
52 g
Dimensions
Width x height x depth:
17.5 x 89 x 58 mm
Standard Types
IK 9138.20 AC/DC 24 V
Article number:
Output:
Auxiliary voltage UH:
Width:
IK 9139 1 A
Article number:
Switching point:
Width:
Ordering example
IK 9138 .20 AC/DC 24 V
IK 9139 AC 175 mA
0036887
1 changeover contact, 1 NO contact
AC/DC 24 V
17.5 mm
0036888
1A
17.5 mm
Nominal voltage
Contacts
Type
Response value
Type
E. DOLD & SÖHNE KG • D-78114 Furtwangen POBox1251•Telephone(+49)77 23 / 654-0 •Telefax (+49) 77 23 / 654-356
e-mail: dold-relays@dold.com • internet: http://www.dold.com
2
IK 9138, IK 9139 / 21.05.03 e


Part Number IK9138
Description Current Monitoring System
Maker DOLD
Total Page 2 Pages
PDF Download

IK9138 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 IK9138 Current Monitoring System
DOLD
2 IK9139 Current Monitoring System
DOLD





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy