B57862
Features
I I I I I I
Improved resistance to humidity Fast response High measuring accuracy Different tolerances available Epoxy resin encapsulation Insulated leads of silver-plated nickel wire, AWG 30
ø0,25 (AWG 30)
50±2 6±1
TNT0392-1
Options Non-standard lead lengths Delivery mode Bulk
..
Dimensions in mm Approx. weight 60 mg
Climatic category (IEC 60068-1) Max. power at 25 °C Resistance tolerance Rated temperature B value tolerance Dissipation factor (in air) Thermal cooling time constant (in air) Heat capacity
P25 ∆R N/R N TN ∆B/B δth τc Cth
55/155/56 60 ± 1 %, ± 3 %, ± 5 % 25 ±1% approx. 1,7 approx. 21 approx. 36 m W
°C m W/K s m J/K
R 25
No. of R/T characteristic 8016 8016 8016
B 25/100 K 3988 3988 3988
Ordering code
Ω
2,8 k 5k 10 k
B57862S0282+040 B57862S0502+040 B57862S0103+040
+: F for ∆RN/RN = ± 1 % H for ∆RN/RN = ± 3 % J for ∆RN/RN = ± 5 % Note The type series S 862 has a specially designed insulation (coating, wire coating) to withstand the immersion test in...