AV60C-048L-033F06-8 Datasheet DC-DC / Industry Standard Isolated Half Brick

Manufacturer: Emerson

Download the AV60C-048L-033F06-8 datasheet PDF. This datasheet also includes the AV60A-048 variant, as both parts are published together in a single manufacturer document.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (AV60A-048-L.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number AV60C-048L-033F06-8
Manufacturer Emerson
File Size 298.06 KB
Description DC-DC / Industry Standard Isolated Half Brick
Download AV60C-048L-033F06-8 Download (PDF)

Overview

Astec Industry Standard 50-150 Watts AV60C Total Power: Input Voltages: No.

of Outputs: 50-150 Watts 48V Single Electrical Specs Input Input range Input Surge Efficiency 36-75 VDC 100V / 100ms 83%@5V Output Load regulation Line regulation Ripple and noise Output voltage adjust range Transient Response • Industry standard pin-out & performance 100°C baseplate temperature (no derating) • Positive and negative enable function • Low output ripple and noise • Remote sense compensation • Fixed frequency switching (300 kHz) 0.2% max 0.

Key Features

  • Control Voltage Adjust Enable 90 to 110% TTL compatible (positive & negative enable options) Environmental Operating case temperature range: -40°C to +100°C Storage temperature: -55°C to +125°C MTBF: >2 million hours Safety UL CSA TUV UL1950 CSA22.2-950 EN60950 34 America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662.