• Part: CXA10-48D05Y
  • Description: DC-DC / Low Power Isolated Industrial
  • Manufacturer: Emerson
  • Size: 248.24 KB
CXA10-48D05Y Datasheet (PDF) Download
Emerson
CXA10-48D05Y

Key Features

  • 4:1 input voltage range
  • Operating ambient temperature of -40°C to +70°C in still air
  • High demonstrated reliability with conservative component deratings
  • Complies with ETS 300 019-1-3/2-3
  • Complies with ETS 300 132-2 input voltage and current requirements
  • Fully compliant with ETS 300 386-1
  • Pin compatible with NFC10 and BXA10 series
  • Basic insulation system (input to output)
  • 2 year warranty The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.3 V, 5 V, 12 V, ±5 V, ±12 V and ±15 V. The series has a wide 4:1 input voltage range of 18Vdc to 75 Vdc. The CXA10 has been designed as a competitive open-frame alternative for the communications market. The product is supplied in the industry standard footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection, short-circuit protection and remote ON/OFF. All components are placed in a fully automated environment. Planar magnetics are used in the design to improve the reliability and reduce the profile of the dc-dc converter. The series has full international safety approvals reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications. Safety UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950-1 File No. E132002 VDE Certificate No.112607. File No. 1040100-3336-0136 CB Report and Certificate to IEC60950-1, #DE 1-30686 Embedded Power for Business-Critical Continuity