• Part: PTH05050W
  • Description: DC-DC / Non-Isolated POLA
  • Manufacturer: Emerson
  • Size: 411.92 KB
Download PTH05050W Datasheet PDF
Emerson
PTH05050W
Features - 6 A output current - 5 V input voltage - Wide-output voltage adjust (0.8 Vdc to 3.6 Vdc) - Auto-track™ sequencing- - Pre-bias start-up capability - Efficiencies up to 95% - Output ON/OFF inhibit - Output voltage sense - Point-of-Load-Alliance (POLA) patible - Available Ro HS pliant - 2 Year Warranty Voltage adjustability Setpoint accuracy Line regulation Load regulation total regulation Minimum load Ripple and noise Temperature co-efficient Transient response (see note 5) (See note 4) - 3.6 Vdc ± 2.0% Vo ±10% m V typ. ±12 m V typ. ± 3% Vo 0A 20 m V pk-pk ± 5% Vo 70 μs recovery time Overshoot/undershoot 100 MV 20 MHz bandwidth -40°C to +85 °C Input Input voltage range Input current Remote ON/OFF Startup time Undervoltage lockout Track input voltage Pin 2 (See note 6, 7) See note 3 No load See note 1 4.5 - 5.5 Vdc 10 m A typ. Positive logic 1 V/ms 3.7 - 4.3 Vdc typ. ± 0.3% Vin Safety UL/c UL CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1, File No. E186249 TÜV Product Service...