  • Low leakage. August 2009 DO-15 Color Band Denotes Cathode Absolute Maximum Ratings.
  • TA = 25°C unless otherwise noted Symbol Parameter Value Units 5391 5392 5393 5394 5395 5396 5397 5398 5399 VRRM Peak Repetitive Reverse Voltage 50 100 200 300 400 500 600 800 1000 IF(AV) Average Rectified Forward Current .375 " lead length @ TA = 75°C 1.5 IFSM Non-repetitive Peak Forwa.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
1N5391 - 1N5399 — General Purpose Rectifiers 1N5391 - 1N5399 General Purpose Rectifiers Features • 1.5 ampere operation at TA = 70°C with no thermal runaway. • High current capability. • Low leakage. August 2009 DO-15 Color Band Denotes Cathode Absolute Maximum Ratings * TA = 25°C unless otherwise noted Symbol Parameter Value Units 5391 5392 5393 5394 5395 5396 5397 5398 5399 VRRM Peak Repetitive Reverse Voltage 50 100 200 300 400 500 600 800 1000 IF(AV) Average Rectified Forward Current .375 " lead length @ TA = 75°C 1.5 IFSM Non-repetitive Peak Forward Surge Current 50 8.