Record of Revision
Version Revise Date Page
Content
1
2005/05/05
Initial release
2005/07/11 1
Modify the module weight from 160g to 114±10g.
3
Modify the scanning direction from “Down to up” to “Up to down”, and from “Up to down” to” Down to up”.
5 6 7 2005/10/25 1
Modify the VCC, AVDD, VGH, VGL, VGH-VGL from “6, 7, 40,-20, 40” to “6.0, 7.0, 40.0, -20.0, 40.0”.
Modify the VCC, AVDD, VGH, VGL, ViAC from “5, 5, 15, -10, 3” to “5.0, 5.0, 15.0, -10.0, 3.0”.
Modify the Input voltage from “12.0Vdc” to “12.0V”.
Divide power consumption into backlight power consumption and panel power consumption.
Modify the lamp life time from 10,000(Min.) to 20,000(Min.).
Modify the frequency from55(Typ.),80(Max.)to
7
50(Typ.