Parameter
Blocking Voltage
Load Current
On-Resistance (max)
LED Current to Operate
Rating
70
150
16
1
Units
VP
mArms / mADC
mA
Transient Protection Characteristics
Peak Pulse Power
600W
VWM
40.2V
Features
Meets Requirements of EN50130-4
(Installation Class 3)
3750Vrms Input/Output Isolation
100% Solid State
Low Drive Power Requirements
(TTL/CMOS Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Applications
Security
Sensor Circuitry
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Aerospace
Industrial Controls
Description
The CPC1317 is a single-pole, normally open
(1-Form-A) solid state relay with bi-directional
transient voltage suppressor (TVS) relay protection,
which is designed to meet the requirements of
EN50130-4 (installation class 3).
The relay output is constructed with efficient
MOSFET switches and photovoltaic die that
use IXYS Integrated Circuits Division's patented
OptoMOS architecture. The input, a highly efficient
GaAlAS infrared LED, controls the optically coupled
output.
The CPC1317 is available in an 8-pin, space-saving
surface-mount package.
Approvals
UL Certified Component: File E76270
CSA Certified Component: Certificate 1172007
EN/IEC 60950-1 Certified Component:
TUV Certificate B 10 05 49410 006
Ordering Information
Part #
CPC1317P
CPC1317PTR
Description
8-Pin Flatpack (50/tube)
8-Pin Flatpack (1000/reel)
Pin Configuration
1
2
3
+ Control
4
– Control
8
TVS +/-
7
TVS -/+
6
Load
5
Load
Pb
DS-CPC1317-R05
e3
Switching Characteristics
of Normally Open Devices
Form-A
I
F
ILOAD
90%
ton
10%
toff
www.ixysic.com
1




IXYS

CPC1317P Datasheet Preview

CPC1317P Datasheet

Single-Pole OptoMOS Relay

No Preview Available !

INTEGRATED CIRCUITS DIVISION
CPC1317
Absolute Maximum Ratings @ 25ºC
Parameter
SSR Output Blocking Voltage
TVS Working Voltage, Maximum
Ratings
70
40.2
Units
VP
V
Reverse Input Voltage
5
V
Input Control Current
Peak (10ms)
50
mA
1
A
Input Power Dissipation 1
150
mW
SSR Output Power Dissipation 2
400
mW
TVS Peak Pulse Power
(IPP=9.3A, 10/1000s pulse)
Isolation Voltage, Input to Output
Operating Temperature
600
W
3750
Vrms
-40 to +85
°C
Storage Temperature
-40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
SSR Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Load Current
Continuous
Peak
On-Resistance 1
Off-State Leakage Current
Switching Speeds
-
IL
-
-
150
mArms / mADC
t=10ms
ILPK
-
-
±400
mAP
IL=150mA, IF=1mA
RON
-
7
16
VL=70VP
ILEAK
-
-
1
µA
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, VL=10V
ton
toff
-
-
2.5
ms
-
-
2.5
VL=50V, f=1MHz
COUT
-
25
-
pF
Input Control Current to Activate 2
Input Dropout Current to Deactivate
Input Voltage Drop
Common Characteristics
IL=150mA
-
IF=5mA
IF
-
-
1
mA
IF
0.1
-
-
mA
VF
0.9
1.2
1.4
V
Capacitance, Input to Output
-
CI/O
-
3
-
pF
1 Measurement taken within 1 second of turn-on time.
2 For applications requiring high temperature operation (> 60oC) a minimum LED drive current of 3mA is required.
TVS Electrical Characteristics
Parameter
Clamping Voltage
Reverse Breakdown Voltage
Reverse Leakage Current
Conditions
Symbol
Min
Typ
Max Units
IPP=9.3A
I=1mA
VWM=40.2V
VC
-
-
66.5
V
VBR
44.4
-
-
V
IL
-
-
5
A
2
www.ixysic.com
R05


Part Number CPC1317P
Description Single-Pole OptoMOS Relay
Maker IXYS
PDF Download

CPC1317P Datasheet PDF






Similar Datasheet

1 CPC1317 Single-Pole OptoMOS Relay
Clare
2 CPC1317 Single-Pole OptoMOS Relay
IXYS
3 CPC1317P Single-Pole OptoMOS Relay
IXYS
4 CPC1317PTR Single-Pole OptoMOS Relay
IXYS





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy