INTEGRATED CIRCUITS DIVISION
Parameters Blocking Voltage Load Current Input Control Current On-Resistance (max)
Ratings 600 100 2 50
Units VP
mArms / mADC mA
Features
• Blocking Voltage: 600V • Low Input Control Current: 2mA • 4000Vrms Input/Output Isolation • Low Drive Power Requirements • Greater Reliability than Electromechanical Relays • FCC Compatible • VDE Compatible • No EMI/RFI Generation • Small 6-Pin Package • Flammability Rating UL 94 V-0
Applications
• Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment—Patient/Equipment Isolation • Security • Industrial Controls
PLA143
600V, 100mA Single-Pole
Normally Open Relay
Description
The PLA143 is a single-pole, normally open (1-Form-A) so