900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf




Infineon Technologies Electronic Components Datasheet

DPS310 Datasheet

Barometric Pressure Sensor

No Preview Available !

DPS310
Digital XENSIVTM Barometric Pressure Sensor for Portable Devices
Product Description
The DPS310 is a miniaturized Digital Barometric Air Pressure Sensor with a high accuracy
and a low current consumption, capable of measuring both pressure and temperature.
The pressure sensor element is based on a capacitive sensing principle which
guarantees high precision during temperature changes. The small package makes the
DPS310 ideal for mobile applications and wearable devices.
The internal signal processor converts the output from the pressure and temperature sensor elements to 24 bit
results. Each unit is individually calibrated, the calibration coefficients calculated during this process are stored
in the calibration registers. The coefficients are used in the application to convert the measurement results to
high accuracy pressure and temperature values. The result FIFO can store up to 32 measurement results,
allowing for a reduced host processor polling rate. Sensor measurements and calibration coefficients are
available through the serial I2C or SPI interface. The measurement status is indicated by status bits or interrupts
on the SDO pin.
Features
Operation range: Pressure: 300 –1200 hPa. Temperature: -40 – 85 °C.
Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode).
Relative accuracy: ± 0.06 hPa (or ±0.5 m)
Absolute accuracy: ± 1 hPa (or ±8 m)
Temperature accuracy: ± 0.5°C.
Pressure temperature sensitivity: 0.5Pa/K
Measurement time: Typical: 27.6 ms for standard mode (16x). Minimum: 3.6 ms for low
precision mode.
Average current consumption: 1.7 µA for Pressure Measurement, 1.5uA for Temperature
measurement @1Hz sampling rate, Standby: 0.5 µA.
Supply voltage: VDDIO: 1.2 – 3.6 V, VDD: 1.7 – 3.6 V.
Operating modes: Command (manual), Background (automatic), and Standby.
Calibration: Individually calibrated with coefficients for measurement correction.
FIFO: Stores up to 32 pressure or temperature measurements.
Interface: I2C and SPI (both with optional interrupt)
Package dimensions: 8-pin LGA, 2.0 mm x 2.5 mm x 1.0 mm.
Green Product (RoHS) Compliant
Typical Applications
Indoor Navigation (floor detection e.g. in shopping malls and parking garages)
Health and Sports (accurate elevation gain and vertical speed)
Outdoor Navigation (GPS start-up time and accuracy improvement, dead-reckoning e.g. in tunnels)
Weather Station('Micro-weather' and local forecasts)
HDD drivers, (leak rate detection in hard disk drives)
Drones (flight stability and height control)
Please read the Important Notice and Warnings at the end of this document
www.infineon.com
V1.1
2019-07-11


Infineon Technologies Electronic Components Datasheet

DPS310 Datasheet

Barometric Pressure Sensor

No Preview Available !

DPS310
Digital XENSIVTM Barometric Pressure Sensor for Portable Devices
Table of contents
Table of contents
1
1.1
2
2.1
2.2
3
3.1
3.2
3.3
3.4
3.5
3.6
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.9.1
4.9.2
4.9.3
4.9.4
5
5.1
5.2
5.3
6
6.1
6.2
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Definitions, acronyms and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pin Configuration and Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Pin Configuration and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Current Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Temperature Transfer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pressure Transfer Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Timing Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Mode transition diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Start-up sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Measurement Precision and Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sensor Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Result Register Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FIFO Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Calibration and Measurement Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
How to Calculate Compensated Pressure Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
How to Calculate Compensated Temperature Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Compensation Scale Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pressure and Temperature calculation flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Measurement Settings and Use Case Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Application Circuit Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
IIR filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Digital interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SPI Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2 V1.1
2019-07-11


Part Number DPS310
Description Barometric Pressure Sensor
Maker Infineon
Total Page 30 Pages
PDF Download

DPS310 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 DPS310 Barometric Pressure Sensor
Infineon





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy