Datasheet4U Logo Datasheet4U.com

LF2005-S - Current Transducer

Features

  • Closed loop (compensated) current transducer using the Hall effect.
  • Insulating plastic case recognized according to UL 94-V0. Special features.
  • IP M = 0 ±3700 A.
  • Ud = 12 kV.
  • TA =.
  • 40 °C (.
  • 50 °C) +85 °C.
  • Secondary connection on shielded cable 3 × 0.5 mm2.
  • Shield between primary and secondary connected to the cable screening.
  • Customer marking. Advantages.
  • Excellent accuracy.
  • Very good linearity.
  • Low temperature drift.
  • O.

📥 Download Datasheet

Datasheet preview – LF2005-S

Datasheet Details

Part number LF2005-S
Manufacturer LEM
File Size 374.76 KB
Description Current Transducer
Datasheet download datasheet LF2005-S Datasheet
Additional preview pages of the LF2005-S datasheet.
Other Datasheets by LEM

Full PDF Text Transcription

Click to expand full text
Current Transducer LF 2005-S/SP8 For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IP N = 2000 A 16143 Electrical data IP N Primary nominal RMS current 2000 A IP M Primary current, measuring range @ ±24 V ÎP max Primary withstand peak current (maximum) 1) 0 ... ±3700 A 80 kA RM Measuring resistance @ TA = 70 °C TA = 85 °C with ±15 V with ±24 V @ ±1800 A max @ ±2100 A max @ ±2200 A max @ ±2000 A max @ ±3000 A max @ ±3500 A max @ ±3700 A max R R M min M max 0 24.4 @ ±1760 A 2) 0 5.5 @ ±2050 A 2) 0 4.2 3 27.2 3 10.2 @ ±2900 A 2) 3 5.3 @ ±3400 A 2) 3 3.
Published: |