Description
The 2920L Series PTC provides surface mount overcurrent
protection for medium voltage (≤60V) applications where
resettable protection is desired.
Features
RoHS compliant, lead-free
and halogen-free
Fast response to fault
currents
High voltage
Low-profile
Applications
IEEE 1394 port protection
Powered ethernet port
protection (IEEE 802.3 af)
Automotive electronic
control module protection
Low voltage telecom
equipment protection
Agency Approvals
Agency
Agency File Number
E183209
R50119118
Electrical Characteristics
Part Number
2920L030
2920L050
2920L075
2920L075/60
2920L100
2920L110/60
2920L125
2920L150
2920L185
2920L200
2920L200/24
2920L250
2920L260
2920L260/24
2920L300
2920L300/15
2920L330/24
2920L400/15
2920L500/16
2920L600/12
2920L600/16
2920L700/12
Marking
LF030
LF050
LF075
LF075-60
LF100
LF110
LF125
LF150
LF185
LF200
LF200-24
LF250
LF260
LF260-24
LF300
LF300-15
LF330
LF400
LF500-16
LF600-12
LF600-16
LF700-12
I hold
(A)
I trip
V max
(A) (Vdc)
0.30 0.60 60
0.50 1.00 60
0.75 1.50 30
0.75 1.50 60
1.10 2.20 33
1.10 2.20 60
1.25 2.50 15
1.50 3.00 33
1.85 3.70 33
2.00 4.00 15
2.00 4.00 24
2.50 5.00 15
2.60 5.00
6
2.60 5.00 24
3.00 5.00
6
3.00 5.00 15
3.3 5.50 24
4.00 8.00 15
5.00 10.00 16
6.00 12.00 12
6.00 12.00 16
7.00 14.00 12
Maximum Time
I max P d typ.
To Trip
(A)
(W)
Current
Time
(A)
(Sec.)
10 1.50
1.50
3.00
10 1.50
2.50
4.00
40
1.50
8.00
0.30
10
1.50
8.00
0.30
40
1.50
8.00
0.50
20 2.00 8.00
0.50
40
1.50
8.00
2.00
40
1.50
8.00
2.00
40
1.50
8.00
2.50
40
1.50
8.00
5.00
40
1.50
8.00
5.00
40
1.50
8.00
5.00
40
1.50
8.00
10.00
40
1.50
8.00
5.00
40
1.50
8.00
20.00
40
1.50
8.00
20.00
40
2.0
8.00
5.00
40 1.50 20.00
4.00
40
2.0
20.00
5.00
50 2.00 30.00
2.00
40 2.20 30.00
2.00
50 2.00 35.00
2.00
Resistance
R min
(Ω)
1.200
0.350
0.350
0.300
0.120
0.120
0.070
0.080
0.050
0.050
0.050
0.035
0.025
0.025
0.015
0.015
0.015
0.010
0.005
0.004
0.004
0.003
R 1max
(Ω)
4.800
1.400
1.000
0.950
0.410
0.410
0.250
0.230
0.150
0.125
0.125
0.085
0.075
0.075
0.048
0.048
0.055
0.040
0.025
0.020
0.020
0.018
Agency
Approvals
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
-
-
X
X
I hold = Hold current: maximum current device will pass without tripping in 20°C still air.
I trip = Trip current: minimum current at which the device will trip in 20°C still air.
V max = Maximum voltage device can withstand without damage at rated current (I max)
I max = Maximum fault current device can withstand without damage at rated voltage (Vmax)
P d = Power dissipated from device when in the tripped state at 20°C still air.
R min = Minimum resistance of device in initial (un-soldered) state.
R typ = Typical resistance of device in initial (un-soldered) state.
R 1max = Maximum resistance of device at 20°C measured one hour after tripping or reflow soldering of 260°C for
20 sec.
Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.
© 2021 Littelfuse, Inc.
1
Specifications are subject to change without notice.
Revised: GD. 04/08/21




Littelfuse

2920L100 Datasheet Preview

2920L100 Datasheet

Resettable PTCs

No Preview Available !

2920L Series
Surface Mount
PTCs Datasheet
Temperature Rerating
Ambient Operation Temperature
-40°C
-20°C
0°C
20°C
40°C
50°C
Part Number
Hold Current (A)
2920L030
0.45
0.40
0.35
0.30
0.25
0.23
2920L050
0.76
0.67
0.59
0.50
0.42
0.38
2920L075
1.13
1.01
0.88
0.75
0.62
0.56
2920L075/60
1.13
1.01
0.88
0.75
0.62
0.56
2920L100
1.66
1.47
1.29
1.10
0.91
0.83
2920L110/60
1.66
1.47
1.29
1.10
0.91
0.83
2920L125
1.89
1.68
1.46
1.25
1.04
0.94
2920L150
2.27
2.01
1.76
1.50
1.25
1.13
2920L185
2.80
2.47
2.17
1.85
1.54
1.39
2920L200
3.02
2.68
2.34
2.00
1.66
1.50
2920L200/24
3.14
2.77
2.42
2.00
1.73
1.56
2920L250
3.78
3.35
2.93
2.50
2.08
1.88
2920L260
3.64
3.25
2.91
2.60
2.26
2.08
2920L260/24
3.64
3.25
2.91
2.60
2.26
2.08
2920L300
4.53
4.02
3.51
3.00
2.52
2.26
2920L300/15
4.20
3.85
3.44
3.00
2.69
2.50
2920L330/24
4.60
4.20
3.75
3.30
2.95
2.75
2920L400/15
5.50
5.00
4.50
4.00
3.40
3.10
2920L500/16
7.55
6.70
5.85
5.00
4.15
3.75
2920L600/12
8.58
7.83
7.05
6.00
5.27
4.87
2920L600/16
8.58
7.83
7.05
6.00
5.27
4.87
2920L700/12
9.48
8.73
7.92
7.00
6.36
5.88
Notes: The temperature rerating data is only for reference, please contact Littelfuse technical support for detail temperature rerating information.
60°C
0.20
0.33
0.50
0.50
0.73
0.73
0.83
1.00
1.22
1.32
1.38
1.65
1.95
1.95
1.99
2.31
2.50
2.80
3.30
4.48
4.48
5.41
70°C
0.17
0.29
0.44
0.44
0.64
0.64
0.73
0.87
1.07
1.16
1.20
1.45
1.74
1.74
1.75
2.12
2.25
2.50
2.90
4.05
4.05
4.83
Average Time Current Curves
Temperature Rerating Curve
85°C
0.14
0.23
0.34
0.34
0.50
0.50
0.56
0.74
0.85
0.90
0.98
1.13
1.48
1.48
1.34
1.83
1.70
2.10
2.25
3.38
3.38
3.94
170%
150%
130%
110%
100
90%
70%
10
50%
30%
10%
1
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 85
Temperature (°C)
0.1
Note: Typical Temperature rerating curve, refer to table for rerating data
0.01
0.1
1
10
100
Current in Amperes
The average time current curves and Temperature Rerating curve performance is affected by a number
or variables, and these curves provided as guidance only. Customer must verify the performance in their
application.
2
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: GD. 04/08/21


Part Number 2920L100
Description Resettable PTCs
Maker Littelfuse
PDF Download

2920L100 Datasheet PDF






Similar Datasheet

1 2920L100 Resettable PTCs
Littelfuse





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy