Datasheet4U Logo Datasheet4U.com

LRD - Max. Device Surface Temperature

Key Features

  • www. DataSheet4U. com Dimensions (mm) S: one slot Dimensions (mm) Model Fig LRD190 LRD190S LRD260 LRD260S LRD380 LRD450 LRD550 LRD600 LRD730 1 2 1 2 1 1 1 1 1 A Min Max 19.9 19.9 20.9 20.9 24.0 24.0 35.0 24.0 27.1 22.1 22.1 23.1 23.1 26.0 26.0 37.0 26.0 29.1 B Min Max 4.9 4.9 4.9 4.9 6.9 9.9 6.9 13.9 13.9 5.5 5.5 5.5 5.5 7.5 10.5 7.5 14.5 14.5 C Min Max 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D Min 5.5 5.5 4.1 4.1 5.3 5.3 5.3 4.1 4.1 E Min Max 3.9 3.9 3.9 3.

📥 Download Datasheet

Datasheet Details

Part number LRD
Manufacturer Littelfuse
File Size 100.64 KB
Description Max. Device Surface Temperature
Datasheet download datasheet LRD Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
POLYFUSE® RESETTABLE FUSES LRD Strap Type, 15 V / 20 V Standard UL 1434 1st Edition CSA C22.2 No. 0 CSA TIL No. CA-3A cULus Recognition TÜV The LRD product series are designed to reduce the device’s resistance at the same hold current rating. The smaller thermal mass of these devices also provide benefit of faster trip time and increase the battery safety level. The LRD devices are ideally suited for battery packs used for portble computer and camcorder applications. Specifications Packaging A small pack D standard Materials Insulating material: Polyester Tape Terminals: Nickel Max. Device Surface Temperature in Tripped State 125 °C Operating / Storage Temperature -40 ºC to +85 ºC (consider derating) Humidity Ageing +85 °C, 85 % R.H.