MicroCapacitance (MC) SC SIDACtor Device
MicroCapacitance (MC) SC SIDACtor Device
The DO-214AA SC MC SIDACtor series is intended for applications sensitive to load
values. Typically, high speed connections require a lower capacitance. CO values for the
MicroCapacitance device are 40% lower than a standard SC part.
This MC SIDACtor series is used to enable equipment to meet various regulatory
requirements including GR 1089, IEC 60950, UL 60950, and TIA-968-A (formerly known as
FCC Part 68). Contact factory regarding ITU K.20, K.21, and K.45.
Electrical Parameters
Part
Number *
P0080SC MC
P0300SC MC
P0640SC MC
P0720SC MC
P0900SC MC
P1100SC MC
P1300SC MC
P1500SC MC
P1800SC MC
P2300SC MC
P2600SC MC
P3100SC MC
P3500SC MC
VDRM
Volts
6
25
58
65
75
90
120
140
170
190
220
275
320
VS
Volts
25
40
77
88
98
130
160
180
220
260
300
350
400
* For surge ratings, see table below.
VT
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
IDRM
µAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
IS
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
IT
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
IH
mAmps
50
50
150
150
150
150
150
150
150
150
150
150
150
CO
pF
55
35
60
60
60
50
50
50
40
40
40
40
40
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
Surge Ratings
Series
C
IPP
2x10 µs
Amps
500
IPP
8x20 µs
Amps
400
IPP
10x160 µs
Amps
200
IPP
10x560 µs
Amps
150
IPP
10x1000 µs
Amps
100
ITSM
60 Hz
Amps
30
di/dt
Amps/µs
500
http://www.littelfuse.com
+1 972-580-7777
2-6
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide