Description | of reflected ripple current testing method. Unit mA VDC Output Specifications Item Operating Conditions Voltage Accuracy Min. Typ. Max. Unit See output regulation curve (Fig. 1) Linear Regulation Input voltage change: ±1% -- -- 1.2 -- Load Regulation Ripple & Noise* Temperature Coefficient 10%-100% load 20MHz bandwidth Full load -- 8 15 % --- 30 75 mVp-p -- ±0.02 -- %... |
Features |
Ultra-small, ultra-thin DFN package (13.20 x 7.00 x 3.10mm) Isolation capacitance as low as 15pF I/O isolation test voltage 3k VDC, O1/O2 isolation test voltage 1.5k VDC Operating ambient temperature range: -40℃ to +125℃ High efficiency up to 87% Continuous short-circuit protection Patent Protection RoHS D050505T-1WR4 are speci... |
Datasheet | D050505T-1WR4 Datasheet - 2.39MB |