900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






MacMic

MM30FU60K Datasheet Preview

MM30FU60K Datasheet

FRED

No Preview Available !

June 2020
Version 03
MM30FU60K
600V 30A FRED
RoHS Compliant
PRODUCT FEATURES
APPLICATIONS
Ultrafast Recovery Time
Freewheeling, Snubber, Clamp
Low Recovery Loss
Inversion Welder
Soft Reverse Recovery Characteristics
PFC
Low Leakage Current
Low Forward Voltage
High Surge Current Capability
Plating Power Supply
Ultrasonic Cleaner and Welder
1
2
Converter & Chopper
DESCRIPTION
UPS
FRED from MacMic utilizes advanced processing techniques to achieve
ultrafast recovery times and higher forward current. Its soft recovery
characteristics and high reliability suit for wide industrial applications.
TTOO--222200
ABSOLUTE MAXIMUM RATINGS (T C =25°C unless otherwise specified)
Symbol
Parameter/Test Conditions
VR
Maximum D.C. Reverse Voltage
VRRM Maximum Repetitive Reverse Voltage
IF(AV)
IF(RMS)
IFSM
PD
Average Forward Current
RMS Forward Current
Non Repetitive Surge Forward Current
Power Dissipation
TC=125
TC=125
TJ=25,t=10ms, 50Hz, Sine
TJ
Junction Temperature
TSTG
Storage Temperature Range
Torque To Heat Sink
RecommendedM3
RthJC Junction to Case Thermal Resistance
Weight
Values
600
30
42
360
188
-55 to +175
-55 to +150
1.1
0.8
2.5
Unit
V
A
W
Nm
/W
g
ELECTRICAL CHARACTERISTICS (T C =25°C unless otherwise specified)
Symbol
Parameter/Test Conditions
IRM
Maximum Reverse Leakage Current
VR =600V
VR =600V, TJ = 150
VF
Forward Voltage
IF=30A
IF=30A,TJ=150
trr
Reverse Recovery Time (IF = 1A, dIF/dt = -200A/μs, VR = 30V)
trr
Reverse Recovery Time (IF = 0.5A, IR=1A, IRR = 0.25A)
Min. Typ. Max. Unit
10
μA
1
mA
2
2.4
V
1.6
22
27
ns
30
40
ns
MacMic Science & Technology Co., Ltd.
Add#18, Hua Shan Zhong Lu, New District, Changzhou City, Jiangsu Province, P. R .of China
1
Tel.+86-519-85163708 Fax+86-519-85162291 Post Code213022 Website www.macmicst.com




MacMic

MM30FU60K Datasheet Preview

MM30FU60K Datasheet

FRED

No Preview Available !

MM30FU60K
ELECTRICAL CHARACTERISTICS (T C =25°C unless otherwise specified)
Symbol
Parameter/Test Conditions
Min. Typ. Max. Unit
trr
Reverse Recovery Time
IRRM
Maximum Reverse Recovery Current
QRR
Reverse Recovery Charge
IF =30A,VR =300V,
dIF/dt = -200A/μs
35
ns
3
A
105
nC
trr
Reverse Recovery Time
IRRM
Maximum Reverse Recovery Current
QRR
Reverse Recovery Charge
IF =30A,VR =300V,
dIF/dt = -200A/μs ,TJ=150
140
7.5
535
ns
A
nC
60
25
50
150
40
30
20
10
0
0 0.5 1 1.5 2 2.5 3
VF(V)
Figure 1. Forward Voltage Drop vs Forward Current
16
25
150
12
8
4
VR=300V
IF=30A
0
100
200
300
400
500
dIF/dt(A/μs)
Figure 3. Reverse Recovery Current vs dIF/dt
250
VR=300V
200
IF=30A
25
150
150
100
50
0
100
200
300
400
500
dIF/dt(A/μs)
Figure 2. Reverse Recovery Time vs dIF/dt
1200
1000
25
150
VR=300V
IF=30A
800
600
400
200
0
100
200
300
400
500
dIF/dt(A/μs)
Figure 4. Reverse Recovery Charge vs dIF/dt
2


Part Number MM30FU60K
Description FRED
Maker MacMic
PDF Download

MM30FU60K Datasheet PDF






Similar Datasheet

1 MM30FU60K FRED
MacMic
2 MM30FU60PC FRED
MacMic





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy