MAX30101
High-Sensitivity Pulse Oximeter and
Heart-Rate Sensor for Wearable Health
General Description
The MAX30101 is an integrated pulse oximetry and
heart-rate monitor module. It includes internal LEDs,
photodetectors, optical elements, and low-noise electronics
with ambient light rejection. The MAX30101 provides a
complete system solution to ease the design-in process
for mobile and wearable devices.
The MAX30101 operates on a single 1.8V power supply
and a separate 5.0V power supply for the internal LEDs.
Communication is through a standard I2C-compatible
interface. The module can be shut down through software
with zero standby current, allowing the power rails to
remain powered at all times.
Applications
● Wearable Devices
● Fitness Assistant Devices
● Smartphones
● Tablets
Benefits and Features
● Heart-Rate Monitor and Pulse Oximeter Sensor in
LED Reflective Solution
● Tiny 5.6mm x 3.3mm x 1.55mm 14-Pin Optical
Module
• Integrated Cover Glass for Optimal, Robust
Performance
● Ultra-Low-Power Operation for Mobile Devices
• Programmable Sample Rate and LED Current for
Power Savings
• Low-Power Heart-Rate Monitor (< 1mW)
• Ultra-Low Shutdown Current (0.7µA, typ)
● Fast Data Output Capability
• High Sample Rates
● Robust Motion Artifact Resilience
• High SNR
● -40°C to +85°C Operating Temperature Range
Ordering Information appears at end of data sheet.
System Diagram
APPLICATIONS
HARDWARE FRAMEWORK
DRIVER
HOST (AP)
I2C
MAX30101
LED DRIVERS
ELECTRICAL OPTICAL
RED/IR/GREEN
LED
DIGITAL NOISE
CANCELLATION
DATA
FIFO
18-BIT
CURRENT ADC
AMBIENT LIGHT
CANCELLATION
PHOTO
DIODE
PACKAGING COVER GLASS
HUMAN
SUBJECT
AMBIENT
LIGHT
19-8453; Rev 2; 10/18


Maxim Integrated Semiconductor Electronic Components Datasheet

MAX30101 Datasheet

High-Sensitivity Pulse Oximeter and Heart-Rate Sensor

No Preview Available !

MAX30101
High-Sensitivity Pulse Oximeter and
Heart-Rate Sensor for Wearable Health
Absolute Maximum Ratings
VDD to GND..........................................................-0.3V to +2.2V
GND to PGND.......................................................-0.3V to +0.3V
VLED+ to PGND....................................................-0.3V to +6.0V
All Other Pins to GND...........................................-0.3V to +6.0V
Output Short-Circuit Current Duration........................Continuous
Continuous Input Current into Any Terminal.....................±20mA
Continuous Power Dissipation (TA = +70°C)
OESIP (derate 5.5mW/°C above +70°C).....................440mW
Operating Temperature Range........................... -40°C to +85°C
Junction Temperature.........................................................+90°C
Soldering Temperature (reflow) .......................................+260°C
Storage Temperature Range............................. -40°C to +105°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only; functional operation of the device at these or any
other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device
reliability.
Package Information
PACKAGE TYPE: 14 OESIP
Package Code
Outline Number
Land Pattern Number
THERMAL RESISTANCE, FOUR-LAYER BOARD
Junction to Ambient (θJA)
Junction to Case (θJC)
F143A5+1
21-1048
90-0602
180°C/W
150°C/W
Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board.
For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial.
For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”,
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing
pertains to the package regardless of RoHS status.
Electrical Characteristics
(VDD = 1.8V, VLED+ = 5.0V, TA = +25°C, min/max are from TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA =
25°C.) (Note 1)
PARAMETER
POWER SUPPLY
Power-Supply Voltage
LED Supply Voltage
VLED+ to PGND
Supply Current
Supply Current in Shutdown
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
VDD
Guaranteed by RED and IR count
tolerance
1.7 1.8 2.0 V
VLED+
Guaranteed by PSRR of LED driver
(RED and IR LED only)
Guaranteed by PSRR of LED driver
(GREEN LED only). TA = 25°C
3.1 3.3 5.0
V
4.5 5.0 5.5
IDD
SpO2 and HR mode, PW = 215µs, 50sps
IR only mode, PW = 215µS, 50sps
600 1100
600 1100
µA
ISHDN TA = +25°C, MODE = 0x80
0.7 2.5
µA
www.maximintegrated.com
Maxim Integrated 2


Part Number MAX30101
Description High-Sensitivity Pulse Oximeter and Heart-Rate Sensor
Maker Maxim Integrated
Total Page 30 Pages
PDF Download

MAX30101 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 MAX3010 8-Channel Level Translators
Maxim Integrated Products
2 MAX30100 Pulse Oximeter and Heart-Rate Sensor IC
Maxim Integrated
3 MAX30101 High-Sensitivity Pulse Oximeter and Heart-Rate Sensor
Maxim Integrated
4 MAX30102 High-Sensitivity Pulse Oximeter and Heart-Rate Sensor
Maxim Integrated
5 MAX30105 MAX30105 High-Sensitivity Optical Sensor
Maxim Integrated





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy