MAX4377
MAX4377 is High-Side Current-Sense Amplifiers manufactured by Maxim Integrated.
- Part of the MAX4376 comparator family.
- Part of the MAX4376 comparator family.
Description
The MAX4376/MAX4377/MAX4378 single, dual, and quad precision high-side current-sense amplifiers are available in space-saving packages. They feature buffered voltage outputs that eliminate the need for gain-setting resistors and are ideal for today’s notebook puters, cell phones, and other systems where current monitoring is critical. These precision devices are offered in three fixed-gain versions of 20, 50, and 100:
GAIN
SUFFIX
20 T
50 F
100 H
For example, MAX4376TAUK is a single high-side amplifier with a gain of 20.
High-side current monitoring is especially useful in battery-powered systems since it does not interfere with the ground path of the battery charger. The input mon-mode range of 0 to +28V is independent of the supply voltage and ensures that the current-sense feedback remains viable even when connected to a battery pack in deep discharge.
The full-scale current reading can be set by choosing the appropriate voltage gain and external-sense resistor. This capability offers a high level of integration and flexibility, resulting in a simple and pact current-sense solution.
The MAX4376/MAX4377/MAX4378 operate over a supply voltage range of +3V to +28V, draw 1m A of supply current per amplifier, and operate over the full automotive tempera- ture range of -40°C to +125°C. These devices have a wide bandwidth of 2MHz, making them suitable for use inside battery-charger control loops. The buffered outputs drive up to 2m A of output current into a ground-referenced load.
The MAX4376 is available in a tiny 5-pin SOT23 package.
The MAX4377/MAX4378 are available in space-saving 8-pin µMAX® and 14-pin TSSOP packages, respectively.
Typical Operating Circuit
0 TO +28V
VSENSE
+3V TO +28V 0.1µF
RSENSE
RS+ RSVCC
ILOAD
MAX4376T/F/H
A/D CONVERTER
OUT GND
LOAD/ BATTERY
Features
- - Low-Cost, Single/Dual/Quad, High-Side Current Sense Amplifiers
- - ±0.5% Typical Full-Scale Accuracy
- - +3V to +28V Supply Operation
- - Adjustable...