NHP-200 Datasheet Text
.DataSheet.co.kr
Coaxial
High Pass Filter
50Ω 185 to 3000 MHz
Features
-55°C to 100°C -55°C to 100°C 0.5W max.
NHP-200+ NHP-200
Maximum Ratings
Operating Temperature Storage Temperature RF Power Input
- rugged shielded case
- other standard and custom NHP models available with wide selection of fco
Connectors N-Type
CASE STYLE: FF57 Model Price Qty. NHP-200(+) $39.95 ea. (1-9)
Applications
- lab use
- transmitters/receivers
- radio munications
+ RoHS pliant in accordance with EU Directive (2002/95/EC)
The +Suffix identifies RoHS pliance. See our web site for RoHS pliance methodologies and qualifications.
High Pass Filter Electrical Specifications
STOPBAND (MHz)
(loss > 40 dB) DC-90 (loss > 20 dB) 90-116 fco (MHz) Nom.
(loss 3 dB) 164
PASSBAND (MHz)
(loss <1 dB) 185-3000 Stopband Typ. 17
VSWR (:1)
Passband Typ. 1.6
Outline Drawing typical frequency response
40 Attenuation, dB
RF IN electrical schematic...