NHP-400 Datasheet Text
.DataSheet.co.kr
Coaxial
High Pass Filter
50Ω 395 to 3200 MHz
Features
-55°C to 100°C -55°C to 100°C 0.5W max.
NHP-400+ NHP-400
Maximum Ratings
Operating Temperature Storage Temperature RF Power Input
- rugged shielded case
- other standard and custom NHP models available with wide selection of fco
CASE STYLE: FF57 Connectors N-Type Model NHP-400(+) Price Qty. $39.95 ea. (1-9)
Applications
- lab use
- transmitters/receivers
- radio munications
+ RoHS pliant in accordance with EU Directive (2002/95/EC)
The +Suffix identifies RoHS pliance. See our web site for RoHS pliance methodologies and qualifications.
High Pass Filter Electrical Specifications
STOPBAND (MHz)
(loss > 40 dB) DC-210 (loss > 20 dB) 210-290 fco (MHz) Nom.
(loss 3 dB) 360
PASSBAND (MHz)
(loss <1 dB) 395-3200 Stopband Typ. 17
VSWR (:1)
Passband Typ. 1.7
Outline Drawing typical frequency response
40 Attenuation, dB
RF IN electrical schematic
RF OUT...