Description
Off No AC applied to any power module in host system
Off Blinking Green
No AC applied to this power module only AC Present & VSTANDBY “on”
Green
54VDC and VSTANDBY “on” and “OK”
Blinking Amber Amber
Power Module Warning Power Module Failure
There is provision for the connection of dual I2C buses for redundancy.This enables two master devices to connect to single slave device(s) within the power module.The power module is provided with a PMBus Management Interface that provides status,
Features
- 1600W Output Power.
- 1.6"(1U) x 14.0" x 4.0"
(41.0mm x 355.6mm x 101.6mm).
- 54VDC Main; PoE compatible.
- 12V SB Output.
- PMBus™ Power Management Bus supported by
dual redundant I2C interfaces.
- N+1 Redundancy Capable; hot swap (up to 8
modules in parallel).
- Active current sharing on 54VDC Main output;
integral bidirectional MOSFET output isolation device.
- Over-Voltage, Over-Current; Over-Temperature Protection.
- Internal variable speed cooling fans.
- .