FOD410, FOD4108, FOD4116, FOD4118
SAFETY AND INSULATION RATINGS
Parameter
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Installation Classifications per DIN VDE 0110/1.89 Table 1,
For Rated Mains Voltage
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Climatic Classification
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Pollution Degree (DIN VDE 0110/1.89)
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ Comparative Tracking Index
< 150 VRMS
< 300 VRMS
Characteristics
I−IV
I−IV
55/100/21
2
175
Symbol
Parameter
Value
Unit
VPR
Input−to−Output Test Voltage, Method A, VIORM x 1.6 = VPR,
Type and Sample Test with tm = 10 s, Partial Discharge < 5 pC
1360
Vpeak
Input−to−Output Test Voltage, Method B, VIORM x 1.875 = VPR,
100% Production Test with tm = 1 s, Partial Discharge < 5 pC
1594
Vpeak
VIORM
VIOTM
Maximum Working Insulation Voltage
Highest Allowable Over−Voltage
External Creepage
850
6000
≥7
Vpeak
Vpeak
mm
External Clearance
≥7
mm
DTI
Distance Through Insulation (Insulation Thickness)
≥ 0.4
mm
TS
Case Temperature (Note 1)
175
°C
IS,INPUT
Input Current (Note 1)
400
mA
PS,OUTPUT Output Power (Note 1)
700
mW
RIO
Insulation Resistance at TS, VIO = 500 V (Note 1)
> 109
W
As per DIN EN/IEC 60747−5−5, this optocoupler is suitable for “safe electrical insulation” only within the safety limit data. Compliance with the
safety ratings shall be ensured by means of protective circuits.
1. Safety limit values − maximum values allowed in the event of a failure.