Datasheet4U Logo Datasheet4U.com

KA2807 Datasheet Ground Fault-circuit Interrupter

Manufacturer: onsemi

Overview: KA2807 Ground Fault Circuit Interrupter.

General Description

The KA2807 is an IC for ground fault circuit interrupters which are intended to provide an electrical shock hazard protection from line to ground fault currents on grounded circuits of 120 V supplies.

Key Features

  • Full Advantage of the UL943.
  • Built.
  • In Voltage Regulator.
  • Sense Coil Ratio.
  • 1000:1.
  • GND/Neutral Coil Ratio.
  • 200:1.
  • Trip Time in Normal Fault and Grounded Neutral Fault is 18 ms Typ.
  • Wide Operating Temperature Range.
  • Excellent ESD Characteristic.
  • 1 mA Output Current Pulse to Trigger SCR.
  • Available in 8 Pin SOIC and 8 Pin MSOP.
  • Pb.
  • Free Device www. onsemi. com.

KA2807 Distributor & Price

Compare KA2807 distributor prices and check real-time stock availability from major suppliers. Prices and inventory may vary by region and order quantity.