900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Omron

A8GS Datasheet Preview

A8GS Datasheet

Remote Reset Rocker Switch

No Preview Available !

New Product
Remote Reset Rocker Switch
A8GS
Minimum size class in the industry Rocker switch with reset function
• Zero standby power by Reset function.
• High inrush-current durability.
Conforming to TV-8 rating. (Inrush 117A)
• Model variation for Micro loads.
• Model variation of micro load and high capacity combination. (DPST)
It is able to operate micro load and high capacity load at the same time.
• Contact gap of 3 mm minimum.
• UL and cUL standard approved, Conforming to EN standards.
• Model variation for 3.3VDC circuit.
RoHS Compliant (Please refer the Precautions)
Usage example
Saving energy by cutting the standby power.
Saving energy by preventing forgetting to turn OFF main power.
Turning OFF main power by remote.
Turning OFF main power of many equipments at the same time.
* There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.
List of Models
1. Reset function type
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
Reset voltage
Marking on caps
No Marking
Micro load contact terminal × 1
+
-a
b
CT Connector
5V model
A8GS-S1105
A8GS-S1205
3.3V model
A8GS-S1103
A8GS-S1203
A8GS-S1305
A8GS-S1303
SPST
Power contact terminal × 1
+1
2
+1
2
-
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-P1185
A8GS-P1183
A8GS-P1285
A8GS-P1283
A8GS-P1385
A8GS-P1383
-
Solder terminals
5V model
A8GS-P1115
A8GS-P1215
3.3V model
A8GS-P1113
A8GS-P1213
A8GS-P1315
A8GS-P1313
Quantity
per box
50
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
Reset voltage
No Marking
DPST
Micro load contact terminal × 1 + Power contact terminal × 1
+1
2
-a
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
terminals #187 (t=0.8)
5V model
3.3V model
A8GS-C1185
A8GS-C1183
b
Micro load contact terminal : CT Connector
Power contact terminal : Solder terminals
5V model
A8GS-C1115
3.3V model
A8GS-C1113
Marking on caps
A8GS-C1285
A8GS-C1283
A8GS-C1215
A8GS-C1213
A8GS-C1385
A8GS-C1383
A8GS-C1315
A8GS-C1313
Quantity
per box
50
1




Omron

A8GS Datasheet Preview

A8GS Datasheet

Remote Reset Rocker Switch

No Preview Available !

A8GS
Contact Form
1 to 4: Power contact terminal
+, -: Coil terminal
Terminals
Reset voltage
Marking on caps
No Marking
DPST
Power contact terminal × 2
+1
2
-3
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-D1185
A8GS-D1183
A8GS-D1285
A8GS-D1283
A8GS-D1385
A8GS-D1383
4
Solder terminals
5V model
A8GS-D1115
A8GS-D1215
3.3V model
A8GS-D1113
A8GS-D1213
A8GS-D1315
A8GS-D1313
Quantity
per box
50
Note: 1. [ V ] is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)
Note: 2. TV-8 approved model is only for Power switch circuit.
Note: 3. [ 3 ] is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183).
[ 5 ] is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185).
2. Without Reset function type
Contact Form
1 to 4: Power contact terminal
Micro load contact
terminal × 1
a, b: Micro load contact terminal
SPST
Power contact terminal × 1
12
Terminals
Marking on caps
No Marking
ab
CT Connector
A8GS-S1100
A8GS-S1200
A8GS-S1300
Quick-connect
terminals
#187 (t=0.8)
A8GS-P1180
A8GS-P1280
A8GS-P1380
Solder
terminals
A8GS-P1110
A8GS-P1210
A8GS-P1310
DPST
Power contact terminal × 2
12
3
Quick-connect
terminals
#187 (t=0.8)
A8GS-D1180
A8GS-D1280
A8GS-D1380
4
Solder
terminals
A8GS-D1110
A8GS-D1210
A8GS-D1310
Quantity
per box
50
Contact Form
1 to 2 Power contact terminal
a, b: Micro load contact terminal
Terminals
No Marking
DPST
Micro load contact terminal × 1 + Power contact terminal × 1
12
a
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
terminals #187 (t=0.8)
A8GS-C1180
b
Micro load contact terminal : CT Connector
Power contact terminal : Solder terminals
A8GS-C1110
Marking on caps
A8GS-C1280
A8GS-C1210
A8GS-C1380
A8GS-C1310
Note: 4. These models are without reset function, it has same function with standard Rocker switch.
Quantity
per box
50
Ratings
Contact Ratings
Rated voltage
Rated current
(Resistive load)
Power contact terminal
125 VAC
250 VAC
16 A
10 A
Micro load contact terminal
5 VDC
0.2 A
Note: 1. The above ratings were tested under the following conditions:
(1) Ambient temperature : 20 ± 2 °C
(2) Ambient humidity : 65 ± 5 % RH
(3) Switching frequency : 7 times/min
Reset Coil Ratings
Model
Rated voltage,
current
Operating
voltage range
Rated usage cycle
Coil resistance
(Coil temperature: 20 ± 2 °C)
Reset voltage : 5V model
(A8GS-@@@@5)
5VDC 455 mA
4.5 to 5.5 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11 Ω ± 20 %
Reset voltage : 3.3V model
(A8GS-@@@@3)
3.3VDC 300 mA
3.0 to 3.6 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11 Ω ± 20 %
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.
2


Part Number A8GS
Description Remote Reset Rocker Switch
Maker Omron
Total Page 8 Pages
PDF Download

A8GS Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 A8G Reset Rocker Switch
Omron
2 A8GS Remote Reset Rocker Switch
Omron
3 A8GS-T Delay OFF Rocker Switch
Omron





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy