900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Omron

G5Q-1A4-EL2-HA Datasheet Preview

G5Q-1A4-EL2-HA Datasheet

PCB Power Relay

No Preview Available !

G5Q-EL/-EL2/-EL3
PCB Power Relay
A Miniature Power Relay
with high performance
• IEC/EN 60335-1 conformed.
• Coil insulation system: class F (UL1446)
• [Type G5Q-EL]
Higher performance compare with G5Q standard type.
Minimum 100,000 operations durability at 10 A (250 VAC) switching.
• [Type G5Q-EL2]
High inrush capacity performance (Inrush current 40 A).
UL508 TV3 conformed.
• [Type G5Q-EL3]
Ideal for motor switching 3 A with high inrush 30 A
IEC/EN 60079-15 conformed.
RoHS Compliant
Model Number Legend
G 5 Q -@@@- @-—@ -@
123 4 5 6
1. Number of Pole
4. Classification
1 : 1-pole
EL : For Resistive load
2. Contact Form
A : SPST-NO (1a)
EL2 : For Inrush load
EL3 : For Motor load
3. Enclosure rating
None : Flux protection
(-EL type only)
5. Market Code
HA : Home Appliance according
to IEC/EN60335-1
4 : Fully sealed
6. Case Vent Hole
(-EL2, -EL3)
None : No vent hole
VH : Vent hole (-EL type only)
Application Examples
• Home appliances
• Building automation
• Lighting control
• Output of control system
• FA I/O module
Ordering Information
G
5
Q
E
L
/
E
L
2
/
E
L
3
Classification
-EL type
(For Resistive load)
-EL2 type
(For Inrush load)
-EL3 type
(For Motor load)
Contact form
SPST-NO (1a)
SPST-NO (1a)
SPST-NO (1a)
Enclosure rating
Flux protection
(Vent hole type)
Sealed
Sealed
Model
G5Q-1A-EL-HA-VH
G5Q-1A4-EL2-HA
G5Q-1A4-EL3-HA
Rated coil voltage
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Minimum packing unit
100 pcs/tray
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A4-EL2-HA DC12
Rated coil voltage
Note 2. Contact your OMRON sales representative for tube packing models.
Ratings
Coil
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate voltage (V)
Must release voltage (V)
% of rated voltage
5 VDC
80.0
63
12 VDC
33.3
360
75% max.
5% min.
24 VDC
16.7
1440
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Note 4. 5 VDC of coil rated voltage is available only for –EL3
Max. voltage (V)
190%
(at 23°C)
Power consumption
(mW)
Approx. 400
1




Omron

G5Q-1A4-EL2-HA Datasheet Preview

G5Q-1A4-EL2-HA Datasheet

PCB Power Relay

No Preview Available !

G5Q-EL/-EL2/-EL3
PCB Power Relay
Contacts
Load
-EL type (For Resistive load)
Item
Contact type
Contact material
Rated load
Rated carry current
Max. rated voltage
Max. rated current
Characteristics
Flux protection
Single
Ag-Alloy (Cd free)
Resistive load 10 A at 250 VAC
10 A
277 VAC
10 A AC
-EL2 type (For Inrush load)
SPST-NO (1a)
Sealed
-EL3 type (For Motor load)
Sealed
Capacitive load Inrush 40 A (100 μs) / Motor load : Inrush 30 A (0.5 s) /
1 A break at 250 VAC
3 A break cosφ=0.5 at 250 VAC
Item
Classification -EL type (For Resistive load)
-EL2 type (For Inrush load)
-EL3 type (For Motor load)
Contact resistance *1
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance *2
1,000 MΩ min. (at 500 VDC)
Dielectric strength
G
5 Impulse withstand
Q voltage
E
L Vibration resistance
/
E Shock resistance
L
2
/
E Durability
L
3
Between coil and
contacts
Between contacts of the
same polarity
Between coil and
contacts
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
4,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
8 kV (1.2 x 50 μs)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
100 m/s2
10,000,000 operations (18,000 operations per hour)
Resistive load
100,000 operations at 23°C
(operation: ON for 1 sec. OFF for 9
sec.)
Capacitive load
100,000 operations at 23°C
(operation: ON for 1 sec. OFF for 3
sec.)
Motor load
300,000 operations at 23°C
(operation: ON for 1 sec. OFF for 1
sec.)
Failure rate (P level) (reference *3)
10 mA at 5 VDC
Ambient operating temperature
-40°C to 85°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 6.5 g
Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the electric strength was measured.
*3. This value was measured at switching frequency of 120 operation/min.
Engineering Data
Maximum Switching Capacity
(AC)
100
AC resistive load
10
1
1 10 100 1000
Switching voltgate (V)
Ambient Temperature VS.
Maximum Coil Voltage
200
180
160
140
120
100
80
60
40
20
0
-40 -20 0 20 23 40 60 80 100 120
Ambient temperature (°C)
Note. The Maximum coil voltage refers to the
maximum value in a varying of operating
power voltage, not a continuous voltage.
Shock Malfunction
1,000
X
1,000
1,000
Z
Z
1,000
Energized
200 De-energized
1,000
800 X
1,000
Y Unit: m/s2
Sample: G5Q-1A-EL-HA-VH
Shock direction
Number of Relays: 5 pcs
Test conditions: Shock is
applied
Y
X
in ±X, ±Y, and ±Z directions three
times each with without
energizing the Relays to check Y'
X'
Z
Z'
the number of malfunctions.
Requirement: None malfuction
100 m/s2
2


Part Number G5Q-1A4-EL2-HA
Description PCB Power Relay
Maker Omron
Total Page 4 Pages
PDF Download

G5Q-1A4-EL2-HA Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 G5Q-1A4-EL2-HA PCB Power Relay
Omron





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy