900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Omron

MY4ZN-D2 Datasheet Preview

MY4ZN-D2 Datasheet

Miniature Power Relay

No Preview Available !

Miniature Power Relays
MY
New Latching Levers for Circuit Checking
Added to Our Best-selling
MY General-purpose Relays
• Now lead-free to protect the environment.
• VDE certification (Germany).
• Different colors of coil tape for AC and
DC models to more easily distinguish them.
• MY(S) models with latching levers added for
easier circuit checking.
$4.@.:@%4@+@@
Refer to the Common Relay Precautions.
Model Number Structure
Structure
Relays with Plug-in Terminals
PCB terminals
Case-surface
mounting
Classification
Number of With operation
poles
indicator
2
MY2N*
Standard models (compliant with
Electrical Appliances and
3
Material Safety Act)
4
Bifurcated MY2ZN
MY3N
MY4N*
Without operation
indicator
MY2*
MY2Z
MY3
MY4*
With latching lever
MY2IN(S)*
MY4IN(S)*
MY2-02
MY3-02
MY4-02
MY2F
MY3F
MY4F
Bifurcated MY4ZN*
2
MY2N-D2*
MY4Z*
MY2-D*
MY4ZIN(S)*
MY2IN-D2(S)*
MY4Z-02
MY4ZF
Models with diode for coil surge
absorption (DC coil specification
only)
3
4
Bifurcated MY2ZN-D2
MY3N-D2
MY4N-D2*
MY2Z-D
MY3-D
MY4-D*
MY4IN-D2(S)*
---
---
Bifurcated MY4ZN-D2*
MY4Z-D*
MY4ZIN-D2(S)*
Models with CR circuit for coil 2
MY2N-CR*
MY2-CR*
surge absorption (AC coil
specification only)
4
MY4N-CR*
MY4-CR*
MY4IN-CR(S)*
---
Bifurcated MY4ZN-CR*
MY4Z-CR*
MY4ZIN-CR(S)*
Models with high contact
reliability
4 Bifurcated
---
MY4Z-CBG
Plastic sealed models
4
MYQ4N
Bifurcated
MYQ4
MYQ4Z
MYQ4-02
MYQ4Z-02
Latching models (coil latching) 2
MY2K
MY2K-02
Hermetic models
4
Bifurcated
MY4H
MY4ZH
MY4H-0
MY4ZH-0
Note: 1. The models in this table are UL/CSA certified. This is indicated with a certification mark on the products.
(This does not include models with high contact reliability or plastic sealed, latching, or hermetically sealed models.)
2. Models with an asterisk (*) next to them are new versions.
3. The standard models with plug-in terminals, models with coil surge absorption diodes, and models with coil surge absorption CR circuits were used in
combination with the PYF-E and PYFS (2-pole and 4-pole) for the EC Declaration of Conformity. These products display the CE Marking.
4. Products cannot be manufactured for the cells with a diagonal line. Ask your OMRON representative for details on manufacturing products for cells containing
“---” in the above table.
Refer to Connection Socket and Mounting Bracket Selection Table on page 33 in Options for information on the
possible combinations of Models with Plug-in Terminals and Sockets.
1




Omron

MY4ZN-D2 Datasheet Preview

MY4ZN-D2 Datasheet

Miniature Power Relay

No Preview Available !

MY
Miniature Power Relays: MY2
Refer to the standards certifications and compliance
section of your OMRON website for the latest
information on certified models.
Ordering Information 8IFOZPVSPSEFS TQFDJGZUIFSBUFEWPMUBHF
Classification
Model
Rated voltage (V)
Standard products
Made-to-order items
Standard models
MY2
12, 24, 100/110, or 200/220 VAC
12, 24, 48, or 100/110 VDC
110/120 or 220/240 VAC
Models with built-in operation indicators
MY2N
12, 24, 100/110, 110/120, 200/220, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in diodes
MY2-D
12, 24, or 100/110 VDC
48 VDC
Models with built-in diodes and operation
indicators
MY2N-D2
12, 24, 48, or 100/110 VDC
Models with built-in CR circuits
MY2-CR
100/110 or 200/220 VAC
110/120 or 220/240 VAC
Models with built-in CR circuits and operation
indicators
MY2N-CR
100/110 or 200/220 VAC
110/120 or 220/240 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products with voltages other than
the above coil specifications.
3. The above models and specifications are new versions in the MY Series.
4. Except for MY2(N)-CR Relays with the above voltage specifications, all Relays have a height of 53 mm or less.
If Mounting Brackets are required, refer to page 33 for selection information.
Ratings and Specifications
Ratings
Operating Coils (Standard Models)
Item
Rated
voltage (V)
Rated current (mA)
50 Hz
60 Hz
Coil resistance
(Ω)
Coil inductance (H)
Armature
OFF
Armature
ON
Must-
operate
voltage (V)
Must-
release
voltage (V)
Maximum
voltage (V)
Power consumption
(VA, W)
12
106.5
91
46
0.17
0.33
24
53.8
46
180
0.69
1.3
Approx. 1.0 to 1.2
(at 60 Hz)
100/110
AC
110/120
200/220
220/240
11.7/12.9
9.9/10.8
6.2/6.8
4.8/5.3
10/11
8.4/9.2
5.3/5.8
4.2/4.6
3,750
4,430
12,950
18,790
14.54
19.2
54.75
83.5
24.6
32.1
94.07
136.4
30% min. *2
80% max. *1
110% of rated
voltage
Approx. 0.9 to 1.1
(at 60 Hz)
12
72.7
165
0.73
1.37
24
36.3
DC
48
17.6
662
2,725
3.2
5.72
10.6
21.0
10% min. *2
Approx. 0.9
100/110
8.7/9.6
11,440
45.6
86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for the AC rated current and ±15% for the
DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C).
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Contact Ratings
Item
Load Resistive load
Inductive load
(cos φ = 0.4, L/R = 7 ms)
Rated load
5 A at 220 VAC 2 A at 220 VAC
5 A at 24 VDC 2 A at 24 VDC
Rated carry current
5A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration
DPDT
Contact structure
Single
Contact materials
Ag
Item
Type
Standard
models
Model with built-in operation
indicator, diode, or CR circuit
Ambient
operating
temperature*1
55 to 70°C
55 to 60°C*2
Ambient
operating
humidity
5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.
2


Part Number MY4ZN-D2
Description Miniature Power Relay
Maker Omron
PDF Download

MY4ZN-D2 Datasheet PDF






Similar Datasheet

1 MY4ZN-D2 Miniature Power Relay
Omron





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy