1.5SMCJ SERIES
SURFACE MOUNT TRANSIENT VOLTAGE SUPPRESSOR PEAK PULSE POWER 1500 Watt
STAND-OFF VOLTAGE
5 to 220 Volt
Recongnized File # E210467
FEATURES
• For surface mounted applications in order to optimize board space.
• Glass passivated junction
• Low inductance
• Plastic package has Underwriters Laboratory Flammability
Classification 94V-O
• High temperature soldering : 260°C /10 seconds at terminals
• ESD IEC-61000-4-2 Air + 30kV, Contact + 30kV
• Lead free in compliance with EU RoHS 2011/65/EU directive
• Green molding compound as per IEC61249 Std. . (Halogen Free)
MECHANICAL DATA
• Case: JEDEC DO-214AB,Molded plastic over passivated junction.
• Terminals: Solder plated,solderable per MIL-STD-750, Method 2026
• Polarity: Color band denotes cathode end
• Standard Packaging: 16mm tape (EIA-481)
• Weight: 0.0082 ounce, 0.2325 gram
DEVICES FOR BIPOLARAPPLICATIONS
For Bidirectional use C or CA Suffix for types 1.5SMCJ5.0 thru types 1.5SMCJ220.
Electrical characteristics apply in both directions.
MAXIMUM RATINGSAND CHARACTERISTICS
Rating at 25°Cambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
For Capacitive load derate current by 20%.
Rating
Peak Power Dissipation at TA=25OC, tp=1ms (Notes 1)
Peak Pulse Current on tp=10/1000μs waveform (Notes 1)
Typical Thermal Resistance Junction to Air (Notes 2)
Peak Forward Surge Current, 8.3ms Single Half Sine-Wave
Superimposed on Rated Load (Notes 3)
ESD IEC-61000-4-2 (Air)
ESD IEC-61000-4-2 (Contact)
Operating Junction and Storage Temperature Range
Symbol
PPP
IPPM
RθJA
I FSM
VESD
TJ,TSTG
Value
1500
See table
50
200
+30
+30
-55 to +150
Units
W
A
OC / W
A
kV
OC
NOTES :
1.Non-repetitive current pulse, per Fig. 3 and derated above TA=25°Cper Fig. 2.
2.Mounted on 2mm 2 (0.013mm thick) land areas.
3.Measured on 8.3ms, single hal f sine-wave or equivalent s quare wave, duty cycle= 4 pulse s per minutes maxi mum.
4.A transient suppressor is selected according to the working peak reverse voltage (VRWM), which should be equal to or greater than the DC
or continuous peak operating voltage level.
November 30,2015-REV.07
PAGE . 1