SA5.0~SA220CA
GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR POWER 500 Watt
STAND-OFF VOLTAGE
5 to 220 Volt
FEATURES
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O
• Glass passivated chip junction in DO-15 package
• 500W surge capability at 1ms
• Excellent clamping capability
• Low zener impedance
• Fast response time: typically less than 1ps from 0 volts to BV min
• High temperature soldering guaranteed: 260°C/10 seconds/0.375"
,(9.5mm) lead length/5lbs., (2.3kg) tension
• ESD IEC-61000-4-2 Air + 30kV, Contact + 30kV
• Lead free in compliance with EU RoHS 2011/65/EU directive
0.034(0.86)
0.028(0.71)
0.140(3.6)
0.104(2.6)
MECHANICAL DATA
• Case: JEDEC DO-15 molded plastic
• Terminals: Axial leads, solderable per MIL-STD-750, Method 2026
• Polarity: Color band denotes cathode end
• Weight: 0.014 ounce, 0.4 gram
DEVICES FOR BIPOLAR APPLICAIONS
For Bidirectional use C or CA Suffix for types Electrical characteristics apply in both directions.
MAXIMUM RATINGS AND CHARACTERISTICS
Rating at 25°Cambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
For Capacitive load derate current by 20%.
RATING
Peak Pulse Power Dissipation at TA=25°C, tP=1ms(Note 1, Fig.1)
Peak Pulse Current of on tp=10/1000µs waveform (Note 1,Fig.3)
Typical Thermal Resistance Junction to Air Lead Lengths 0.375",
(9.5mm) (Note 2)
Peak Forward Surge Current, 8.3ms Single Half Sine-Wave Superim-
posed on Rated Load (Note 3)
ESD IEC-61000-4-2 (Air)
ESD IEC-61000-4-2 (Contact)
Operating and Storage Temperature Range
SYMBOL
PPP
IPPM
RθJA
IFSM
VESD
TJ , TSTG
VALUE
500
SEE TABLE 1
50
70
+30
+30
-65 to +175
UNITS
Watts
Amps
°C / W
Amps
kV
°C
NOTES :
1.Non-repetitive current pulse, per Fig. 3 and derated above TA=25°C per Fig. 2.
2.Mounted on Copper Leaf area of 1.57in2(40mm2).
3.8.3ms single half sine-wave, duty cycle= 4 pulses per minutes maximum.
4.A transient suppressor is selected according to the working peak reverse voltage (VRWM), which should be equal to or greater than the
DC or continuous peak operating voltage level.
November 12,2015-REV.06
PAGE . 1