900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf




Panasonic Electronic Components Datasheet

LKS1aF-24V Datasheet

power relays

No Preview Available !

TV-5 rated.
High sensitivity: 250mW
1a 5A power relays
VDE LK-S
LK-S RELAYS
RoHS compliant
FEATURES
1. High sensitivity
A nominal operating power of 250mW
and high sensitivity make it ideal for
energy saving (LK relay is 530mW).
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC60065)
2) Surge withstand voltage between
contact and coil: 10,000 V
3. Popular terminal pitch in AV
equipment field
4. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
5. Conforms to the various safety
standards
UL, CSA, VDE, TÜV and SEMKO
approved
TYPICAL APPLICATIONS
• Audio visual equipment
• Office equipment
• Home appliances
ORDERING INFORMATION
LKS 1a F
LK-S relay
Contact arrangement
1a: 1 Form A
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
5V, 9V, 12V, 24V
Notes: Certified by UL, CSA, TÜV and SEMKO
VDE approved type is available. Please consult us for details.
TYPES
Contact arrangement
Nominal coil voltage
5V DC
1 Form A
9V DC
12V DC
24V DC
Standard packing Carton: 100 pcs. Case: 500 pcs.
Note: 6 V, 18 V DC types are also available. Please consult us for details.
Part No.
LKS1aF-5V
LKS1aF-9V
LKS1aF-12V
LKS1aF-24V
RATING
1. Coil data
Nominal coil
voltage
5V DC
9V DC
12V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
50mA
27.8mA
20.8mA
10.4mA
Coil resistance
[±10%] (at 20°C 68°F)
100
324
576
2,304
Nominal operating
power
250mW
Max. applied voltage
(at 20°C 68°F)
6.5V DC
11.7V DC
15.6V DC
31.2V DC
ASCTB80E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e


Panasonic Electronic Components Datasheet

LKS1aF-24V Datasheet

power relays

No Preview Available !

LK-S
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity*1
Insulation resistance (Initial)
Breakdown voltage Between open contacts
(Initial)
Between contact and coil
Electrical
characteristics
Mechanical
characteristics
Expected life
Temperature rise (coil)
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Shock resistance
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)
Conditions
Unit weight
Conditions for operation, transport and storage*3
Max. operating speed
Specifications
1 Form A
Max. 100 m(By voltage drop 6 V DC 1A)
AgSnO2 type
5A 277V AC
1,385VA
277V AC
5A (AC)
100mA, 5V DC
Min. 1,000M(at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 35°C 95°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 5A, at 70°C 158°F)
10,000 V
Max. 15 ms (excluding contact bounce time.)
Max. 5 ms (excluding contact bounce time) (Without diode)
200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 106
Min. 105 (ON:OFF = 1.5s:1.5s, at nominal switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
20 times/min. (at nominal switching capacity)
Approx. 12 g .42 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching power (AC resistive load)
100
10
5
1
0 10 100
Contact voltage, V
2. Coil temperature rise
Sample: LKS1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 0 A, 5A
30
25
20
20°C 5A
20°C 0A
70°C 5A
70°C 0A
15
10
5
00 80
100 120
Coil applied voltage, %V
3. Ambient temperature characteristics and coil
applied voltage
Contact current: 5 A
500
400
Allowable ambient temperatures
against % coil voltages
300
(max. inside the coil tem-
perature set as
115°C 239°F)
200
Cold start
100
Pick-up voltage
00 10 20 30 40 50 60 70 80
Ambient temperature, °C
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
ASCTB80E 201201-T


Part Number LKS1aF-24V
Description power relays
Maker Panasonic
Total Page 4 Pages
PDF Download

LKS1aF-24V Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 LKS1aF-24V 250 mW Slim Power Relay
NAiS
2 LKS1aF-24V power relays
Panasonic





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy