  • Most Popular Power PCB Relay Footprint - T90.
  • 50 Amp 240 VAC General Purpose UL Rating.
  • 2 HP 250 VAC Rating.
  • UL Class F Insulation Standard.
  • Meets UL 508 and UL 873 Spacing with Pin 6 Omitted.
  • Epoxy Sealed, Immersion Cleanable.
  • RoHS Compliant.

📥 Download Datasheet

Datasheet Details

Part number PTRE
Manufacturer Picker
File Size 579.68 KB
Description PCB Relay
Datasheet download datasheet PTRE Datasheet

Full PDF Text Transcription for PTRE (Reference)

Note: Below is a high-fidelity text extraction (approx. 800 characters) for PTRE. For precise diagrams, and layout, please refer to the original PDF.

50 Amp Power PCB Relay PTRE FEATURES  Most Popular Power PCB Relay Footprint - T90  50 Amp 240 VAC General Purpose UL Rating  2 HP 250 VAC Rating  UL Class F Insulati...

View more extracted text
General Purpose UL Rating  2 HP 250 VAC Rating  UL Class F Insulation Standard  Meets UL 508 and UL 873 Spacing with Pin 6 Omitted  Epoxy Sealed, Immersion Cleanable  RoHS Compliant FACTORY RATINGS Load Type Voltage 1 Form A 1 Form B (SPST-NO) (SPST-NC) 1 Form C (SPDT) NO NC Resistive 6,000 Cycles 240 VAC 30 VDC 50 A 35 A 50 A 35 A Load Type E160644 at 40°C Cycles Voltage General Purpose (Resistive) 10,000 50.000 240 VAC/30 VDC 240 VAC/30 VDC 1 Form C (SPDT) NO NC 50 A 35 A 40 A 30 A Lamp 3,000 Cycles 240 VAC TV-5 — TV-5 Electric Ballast 6,000 Cycles 280 VAC 5A — 5A Motor Load 3,000 Cycles 250 VAC 2 HP 1.5 HP 2 HP CH