SMT Power Inductors
High Current Composite Inductor - PA5005.XXXNLT and PM2205.XXXNLT
Height: 5.0mm Max
Footprint: 6.8mm x 6.6mm Max
Current Rating: up to 24Apk
Inductance Range: 0.82uH to 8.2uH
High current, low DCR, and high efficiency
High reliability
Minimized acoustic noise and minimized leakage flux noise
Available in Commercial (PA5005) and Automotive
(PM2205) grades
Electrical Specifications @ 25°C, Operating Temperature Range per Below4
Part Number
Commerical
Automotive6
Inductance
100KHz, 0.1V
Rated3
Current
DC Resistance
TYP. MAX.
Saturation2
Current
(25°C)
(-40°C to 125°C) (-55°C to 155°C) uH±20% A mΩ mΩ
PA5005.821NLT PM2205.821NLT
0.82
21 3.8 4.18
PA5005.102NLT PM2205.102NLT
1
20 4.1 4.52
PA5005.122NLT PM2205.122NLT
1.2
18 5.3 5.83
PA5005.152NLT PM2205.152NLT
1.5
17 5.7 6.3
PA5005.182NLT PM2205.182NLT
1.8
16 6.4 7.1
PA5005.222NLT PM2205.222NLT
2.2
13 7.7 8.5
PA5005.332NLT PM2205.332NLT
3.3
11 11.2 12.5
PA5005.432NLT PM2205.432NLT
4.3
9 15.1 16.2
PA5005.472NLT PM2205.472NLT
4.7
8.5 16.7 18.4
A
24
23
22
19.5
18.5
16
12.5
11
10.5
K Factor
for
Core Loss
132.2
132.2
109.2
93
93
81
64.4
53.4
49.2
Mechanical
D
±0.3
5.3
5.3
5.3
5.3
5.3
5.2
5.2
5.2
5.2
Notes:
1. Actual temperature of the component during system operation (ambient plus
4. The part temperature (ambient+temp rise) should not exceed 125�C under worst
temperature rise) must be within the standard operating range.
case operating conditions. Circuit design, PCB trace size and thickness, airflow and
2. The saturation current is the current at which the initial inductance drops approxi-
other cooling provisions all affect the part temperature. Part temperature should be
mately 30% at the stated ambient temperature. This current is determined by placing
verified in the end application.
the compnent in the specified ambient environment and applying a short duration 5. The PM2205.XXXNLT part numbers are AEC-Q200 and IATF16949 certified. The
pulse current (to eliminate self-heating effect) to the component.
mechanical dimensions are 100% tested in production but do not necessarily meet a
3. The rated current is the DC current required to raise the component temperature by
product capability index (Cpk) >1.33 and therefore may not strictly conform to PPAP.
approximately 40�C. Take note that the components’ performanc varies depending
on the system condition. It is suggested that the component be tested at the system
level, to verify the temperature rise of the component during system operation.
1 power.pulseelectronics.com P809. B (09/18) http://www.power.pulseelectronics.com/contact