AC / DC CONVERTER

No Preview Available !

ReICU
AC/DC CONVERTER
Features
Efficiency up to 84%
3000VAC Isolation
Single/Double output
short circuit protection
Universal Input :85 ~ 264VAC,50/60Hz
Wide temperature -25 to 70
Power modules for PCB Mounting mesign
Plastic case
Model Selection Guide
Order Code
AD30-S05
AD30-S09
AD30-S12
AD30-S15
AD30-S24
AD30-D05
AD30-D12
AD30-D15
AD30-D05-05
AD30-D05-12
AD30-D05-24
Input
AC(V)
DC(V)
165-264
200-370
AD30 Series
30W
Output
Vo(V)
Io(mA)
5 6000
9 3333
12 2500
15 2000
24 1250
+5 +3000
+12 +1250
+15 +1000
5/5 5000/1000
5/12 5000/400
5/24 5000/200
Recommend Efficiency(%)
capacitive(uF)
(Typ)
2200
680
680
680
470
22002200
680/680
680/680
2000/680
2000/680
2000/330
82
83
84
84
85
82
84
84
84
84
84
Input Characteristics
Parameter
Input Voltage Range
Input Frequency
Output Characteristics
Parameter
Output Voltage Accuracy
Load regulation
Line regulation
Ripple and noise
Switching frequency
Transient Recovery Time
Hold-up time
Short circuit Protection
Condition
AC
DC
AC
Min Typ Max Units
85 264 VAC
120 375 VDC
47 440 Hz
Condition
10% 100% load
Vin(Min~Max)
20MHz
Full load,nominal input
25% Load Step Change
Min Typ Max Units
1% %
+0.5 +1
%
+0.5 +1
%
50 100 mVp-p
60 KHz
500 us
50 ms
Continuous,Automatic Recovery
REV:15.1
Page 1 of 3
www.reicu.com
E-mail:service @reicu.com
ReICU
AC/DC CONVERTER
General Characteristics
Parameter
Operating Temperature
Storage
Storage humidity
Cooling
Isolation voltage
Isolation resistance
MTBF
Safety level
Case material
Condition
Case
Free air convection
Input-Output 1mA 1minute
500VDC
2 105
Single output
Others
Min
-25
-40
AD30 Series
Typ Max
+85
+105
+95
3000
500
Class II
Class I
Platic
Units
%
VAC
M
K hours
Temperature Derating Graph Curve
120
100
80
60
40
20
0
-40
80 Metal case
Plastic case
-25 0 25 50 75 100
Operating Temperature( )
Input Voltage Derating Graph Curve
120
100
80
60
Ambient temperature 25
40
Safe Operating Area
20
0
85 120
264 285
Input Voltage(VAC)
Note
1.All the specifications typical at Ta=+25 resistive load, nominal input voltage and rated output current unless otherwise noted.
2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed.
3.Ripple & Noise measurement bandwidth is 0-20MHz.
3.Other input and output voltage may be available, please
4.All AC/DC converters should be externally fused at the front end for protection.
5.Specifications subject to change without notice
Application circuit
AC(L)
Fuse
AC(N)
+Vo
DC/DC
Converter
Cout
0V
Load
(Single output)
AC(L)
Fuse
AC(N)
+Vo1
Cout
DC/DC -Vo1
Converter +Vo2
Cout
-Vo2
)Double output)
Load1
Load2
REV:15.1
Page 2 of 3
www.reicu.com
E-mail:service @reicu.com
ReICU
AC/DC CONVERTER
EMC recommended circuit
AD30 Series
FUSE NTC
L
MOV
N
LCM Cx Cy
R
Cy
FG
L
MOV
MOV
N
FG
+Vo
C1 C2 TVS
-Vo
LOAD
1 FUSE I=3*Vo*Io/
Vin
Recommend 2A/250V(10-30W)
2 NTC: 10D-09
3 MOV: 7D471K
4 LCM: 5-20mH/0.5A
5 Cx: 104/275VAC
6 Cy: 102/400VAC
7 C1: 104/50V
8 C2: Reference value for capacitor
9 TVS: P6KE20CA SMBJ20CA
Mechanical Dimension & Pin Connections
Bottom View
70.0(2.76)
62.0(2.44)
3
Lateral View
1.00
(0.04)
23.5(0.93)
48.0 40.0
(1.89) (1.57)
2
4
5
6
11.5 23.0
(0.45) (0.91)
7
8
1
6.10(0.24)
Note:
Unit:mm(inch)
Pin
Single
Dual
Dual Island
1
NC
NC
NC
2
N
N
N
345678
L +Vo NP NP NP -Vo
L +Vo NP COM NP -Vo
L +Vo2 -Vo2 NP +Vo1 -Vo1
REV:15.1
Page 3 of 3
www.reicu.com
E-mail:service @reicu.com


Part Number AD30-S15
Description AC / DC CONVERTER
Maker REICU
Total Page 1 Pages
PDF Download

AD30-S15 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 AD30-S12 AC / DC CONVERTER
REICU
2 AD30-S15 AC / DC CONVERTER
REICU





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy