Cell size reference
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30 °C max.) Nominal capacity (at 80 m A + 20°C 2.0 V cut of f. The capacity restored by the cell varies according to current drain, temperature and cut off) Open circuit voltage Nominal voltage (at + 20°C) (at 0.06 A + 20°C)
R6
- AA
0.95 Ah
3.0 V 2.8 V 0.5 A
- Low self-discharge rate
(less than 3% after 1 year of storage at + 20ºC) Hermetic glass-to-metal sealing Built-in safety vent (at the negative end of the cell) Meets shock, vibration and other environmental requirements of military specifications Made in UK
Continuous current permitting 50% of the nominal capacity to be achieved at + 20ºC with 2.0 V cut of f. Pulse capability : Typically up to 0.8 A. (The voltage readings may var y according to the pulse characteristics, the temperature and the cell’s previous history. Fitting the cell with a capacitor may be remended in severe conditions. Consult Saft)...