SICF3SV2 Overview
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) Parameters Table SYMBOL UNIT VALUE Electrical data Supply voltage(±5%) VC V ±15 Current consumption IC mA 22+I s 50 Secondary nominal r.m.s. current I SN mA 100 150 Conversion ratio KN 1:2000.
SICF3SV2 Key Features
- Hall effect measuring principle
- Galvanic isolation between primary and secondary circuit
- Low power consumption
- Extended measuring range
- Insulated plastic case recognized according to UL 94-V0
- Very good linearity Excellent accuracy Low temperature drift Wide frequency bandwidth Optimized response time No inserti
- Excellent performance and price