900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






SEC

SIOLSV2 Datasheet Preview

SIOLSV2 Datasheet

Current Sensors

No Preview Available !

 
IPN = 200…2000A,Vout=±4V
Advantages
Easy installation
Small size and space saving
Only one design for wide current
ratings range
High immunity to external interference
  SIOLSV2
Current Sensors
Features
Hall effect measuring principle
Galvanic isolation between primary and
secondary circuit
Low power consumption
Extended measuring range
Isolation voltage 3000V
Industrial applications
DC motor drives
Switched Mode Power Supplies(SMPS)
AC variable speed drives
Uninterruptible Power Supplies(UPS)
Battery supplied applications
Power supplies for welding application
www.DataSheet.net/
Type
SIOLS200V2
SIOLS400V2
SIOLS600V2
SIOLS800V2
SIOLS1000V2
SIOLS2000V2
TYPES OF PRODUCTS
Primary nominal current
Primary current measuring range
r. m. s IPN (A)
200
IP (A)
±400
400 ±800
600 ±1200
800 ±1600
1000
±2000
2000
±3000
General Description
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit (high power) and the secondary circuit (electronic circuit)
1 V2.00 May 1, 2012
Datasheet pdf - http://www.DataSheet4U.co.kr/




SEC

SIOLSV2 Datasheet Preview

SIOLSV2 Datasheet

Current Sensors

No Preview Available !

  SIOLSV2
Current Sensors
Parameters Table
PARAMETERS
Supply voltage(±5%)(1)
Current consumption
Output voltage
Isolation resistance
Output internal resistance
Load resistance(2)
Linearity(3)(0…±IPN)
SYMBOL UNIT
Electrical data
VC V
IC mA
VALUE
±15
±15
Vout V ±4
RIS
R OUT
RL
M>1000
100
K>10
Accuracy - Dynamic performance data
εL
% of IPN
<±1
Accuracy
XG
% of IPN
<±1
Electrical offset voltage
Hysteresis offset voltage
Temperature coefficient of VOE
Temperature coefficient of
V OUT
Response time
Frequency bandwidth(4)
Ambient operating temperature
Ambient storage temperature
Mass
Rated isolation voltage rms
Rms voltage for AC
isolation test
VOE
VOH
TCVOE
mV
mV
mV/K
<±20
<±10
<±1
TCVOUT
%/K
www.DataSheet.net/
<±0.1
tr μS <5
BW kHz DC~25
General data
TA °C -40 ~ +85
TS °C -40 ~ +105
m g 300
Isolation characteristics
Vb V 1000
Vd kV
3
CONDITIONS
@ ± IPN, RL = 10 k,
TA = 25°C
@ 500 VDC
@ IPN, TA = 25°C
@ IPN, TA = 25°C
(excluding offset)
@TA = 25°C
@ IP= 0
@ 90% of IPN
@-3dB
@50 Hz, 1 min
Notes:
1) Operating at ±12V VC<±15V will reduce the measuring range.
2) If the customer uses 10KΩ of the load resistor, the primary current has to be limited as the
nominal.
3) Linearity data exclude the electrical offset.
4) Please refer to derating curves in the technical file to avoid excessive core heating at high
frequency.
2 V2.00 May 1, 2012
Datasheet pdf - http://www.DataSheet4U.co.kr/


Part Number SIOLSV2
Description Current Sensors
Maker SEC
PDF Download

SIOLSV2 Datasheet PDF





Similar Datasheet

1 SIOLSV2 Current Sensors
SEC





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy