Datasheet4U Logo Datasheet4U.com

LB1412M - Level Meter for 12 LEDs

Description

of constants of each block 2-1 R3, R4 (R11, R12) The gain of amp1 depends on R3, R4.

Gain of amp 1 = R3/R4 times.

The gain of amp1 must not exceed 4 times (12 dB).

Features

  • Package Dimensions unit : mm . Bar-shaped display of input level by means of 12 LEDs. . High-order 5 dots with peak hold. . Built-in oscillator for peak hold reset. Requires 1pce each of . . . . . external C, R. Uses either oscillator at the time of stereo operation. Also capable of resetting manually. Capable of constant-current driving low-order 7 dots (green LED). Constant-current value variable with an external resistor. Lower current drain available by connecting green LEDs in series. Bui.

📥 Download Datasheet

Datasheet preview – LB1412M

Datasheet Details

Part number LB1412M
Manufacturer SANYO (now Panasonic)
File Size 72.36 KB
Description Level Meter for 12 LEDs
Datasheet download datasheet LB1412M Datasheet
Additional preview pages of the LB1412M datasheet.
Other Datasheets by Sanyo

Full PDF Text Transcription

Click to expand full text
Ordering number: EN1593B Monolithic Digital IC LB1412M Level Meter for 12 LEDs Functions and Features Package Dimensions unit : mm . Bar-shaped display of input level by means of 12 LEDs. . High-order 5 dots with peak hold. . Built-in oscillator for peak hold reset. Requires 1pce each of . . . . . external C, R. Uses either oscillator at the time of stereo operation. Also capable of resetting manually. Capable of constant-current driving low-order 7 dots (green LED). Constant-current value variable with an external resistor. Lower current drain available by connecting green LEDs in series. Built-in input amplifier. Requires no other light-up level adjustment than adjustment for 0 dB.