Elektronische Bauelemente
SMCJ Series CR-C
Voltage 5V~440V
1500W Peak Power Surface Mount TVS
RoHS Compliant Product
A suffix of “-C” specifies halogen-free and lead-free
FEATURES
Qualified to AEC-Q101 standards for high reliability
Glass passivated junction
Very fast response time
Plastic package Underwriters Laboratory Flammability
Classification 94V-0
Low incremental surge resistance, Excellent clamping capability
1500W peak pulse power capability with a 10/1000us
waveform, repetition rate (duty cycle): 0.01%
High temperature soldering guaranteed:
260°C/10 seconds
MECHANICAL DATA
Case: Molded Plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: Solder-able per MIL-STD-202, method 208 guaranteed
Polarity: Color band denotes cathode end except Bidirectional
PACKAGE INFORMATION
Package
MPQ
SMC
3K
Leader Size
13 inch
SMC
B
AC
D
GE
F
H
REF.
A
B
C
D
Millimeter
Min. Max.
2.75 3.15
6.6 7.11
5.59 6.22
2.00 2.62
REF.
E
F
G
H
Millimeter
Min. Max.
- .203
7.75 8.13
0.76 1.52
0.15 0.31
ORDER INFORMATION
Part Number
Type
SMCJ Series CR-C Lead (Pb)-free and Halogen-free
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Ratings
Symbol
Value
Minimum Peak Pulse Power Dissipation 1 2 @10/1000us waveform
Minimum Peak Pulsed Current 1 @10/1000us waveform
Peak Forward Surge Current 3 @8.3ms single Half Sine-Wave
PPP
IPP
IFSM
1500
(See next table.)
200
Operating Junction and Storage Temperature Range
TJ, TSTG
-55~150
Thermal Resistance Ratings
Thermal Resistance Junction-Ambient 2
RθJA
Thermal Resistance Junction-Lead 2
RθJL
Notes:
1.
2.
3.
Non-repetitive current pulse, on Fig. 3 and derated above TA=25°C per Fig. 2.
Mounted on copper pad area of 0.31 x 0.31” (8.0 x 8.0 mm) to each terminal.
Measured on 8.3ms single half sine-wave or equivalent square wave for unidirectional device only.
75
15
Units
W
A
A
°C
°C/ W
http://www.SeCoSGmbH.com/
27-Feb-2020 Rev. A
Any changes of specification will not be informed individually.