900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf




Sharp Electronic Components Datasheet

S116S02 Datasheet

(S112S02 / S116S02) SIP Type SSR

No Preview Available !

www.DataSheet4U.com
S112S01 Series
S116S01 Series
s Features
1. Compact, high radiation resin
mold package
2. RMS ON-state current
S112S01 Series : 12Arms at TC <= 70˚C
( With heat sink)
S116S01 Series : 16Arms at TC <= 60˚C
( With heat sink)
3. Built-in zero-cross circuit
(S112S02 / S212S02 / S116S02 / S216S02 )
4. High repetitive peak OFF-state voltage
S112S01 / S112S02 / S116S01 / S116S02
VDRM : 400V
S212S01 / S212S02 / S216S01 / S216S02
VDRM : 600V
5. Isolation voltage between input and output
(Viso : 4 000Vrms )
6. Recognized by UL, file No. E94758
S112S01 / S112S02
S116S01 / S116S02
7. Approved by CSA, No. 63705
S112S01 / S112S02
S116S01 / S116S02
s Applications
1. Copiers, laser beam printers
2. Automatic vending machines
3. FA equipment
S112S01 Series/S116S01 Series
SIP Type SSR for Medium
Power Control
s Outline Dimensions
(Unit : mm )
* The metal parts marked*
are common to terminal 1 .
g Do not allow external connection.
( ) : Typical dimensions
A (Model No.)
B
S112S01
12A125VAC
S112S02
S116S01
16A125VAC
S116S02
S212S01
S212S02 12A250VAC
S216S01
16A250VAC
S216S02
18.5 ± 0.2
16.4 ± 0.3
φ 3.2 ± 0.2
*
5.5 ± 0.2
A
4 - 1.1 ± 0.2
4 - 1.25 ± 0.3
4 - 0.8 ± 0.2
B
+-
1 23 4
(5.08) (7.62)
Internal connection diagram
S112S01/S116S01
S212S01/S216S01
(2.54)
0.6 ± 0.1 (1.4)
S112S02/S116S02
S212S02/S216S02
Zero-cross
circuit
1 2 34
1 Output (Triac T2)
2 Output (Triac T1)
3 Input ( + )
4 Input ( - )
1 2 34
1 Output (Triac T2)
2 Output (Triac T1)
3 Input ( + )
4 Input ( - )
s Model line-ups
For phase control
No built-in zero-cross circuit
Built-in zero-cross circuit
For 100V
lines
S112S01
S116S01
S112S02
S116S02
For 200V
lines
S212S01
S216S01
S212S02
S216S02
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”


Sharp Electronic Components Datasheet

S116S02 Datasheet

(S112S02 / S116S02) SIP Type SSR

No Preview Available !

S112S01 Series/S116S01 Series
s Absolute Maximum Ratings
Input
Output
Parameter
Forward current
Reverse voltage
RMS ON-state
current
S112S01 Series
S116S01 Series
*1 Peak one cycle
S112S01 Series
surge current
S116S01 Series
Repetitive peak
OFF-state voltage
Non-repetitive peak
OFF-state voltage
S112S01 / S112S02
S116S01 / S116S02
S212S01 / S212S02
S216S01 / S216S02
S112S01 / S112S02
S116S01 / S116S02
S212S01 / S212S02
S216S01 / S216S02
Critical rate of rise of ON-state current
Operating frequency
*2 Isolation voltage
Operating temperature
Storage temperature
*3Soldering temperature
Symbol
IF
VR
IT
I surge
VDRM
VDSM
dI/dt
f
Viso
Topr
Tstg
Tsol
(Ta = 25˚C )
Rating
50
6
*412
*516
120
160
400
600
400
600
50
45 to 65
4 000
- 25 to + 100
- 30 to + 125
260
Unit
mA
V
A rms
A rms
A
A
V
V
V
V
A/µ s
Hz
V rms
˚C
˚C
˚C
*1 AC 60Hz sine wave, Tj = 25˚C
start
*2 AC 60Hz for 1 minute, 40 to 60
% RH. Apply voltages between
input and output by the
dielectric withstand voltage
tester with zero-cross circuit.
( Input and output shall be short-
ed respectively) .
( Note )
When the isolation voltage is
necessary at using external
heat sink, please use the in-
sulation sheet.
*3 For 10 seconds
*4 TC<=70˚C
*5 TC<=60˚C
s Electrical Characteristics
Parameter
Input
Forward voltage
Reverse current
Repetitive peak OFF-state current
ON-state voltage
S112S01 Series
S116S01 Series
Holding current
Output
Critical rate of rise of OFF-state voltage
Transfer
charac-
teristics
Critical rate of rise of commutating
OFF-state voltage
Zero-cross voltage
Minimum trigger
current
S112S02 / S212S02
S116S02 / S216S02
S112S01 / S212S01
S116S01 / S216S01
S112S02 / S212S02
S116S02 / S216S02
Isolation resistance
Turn-on time
S112S01 / S212S01
S116S01 / S216S01
S112S02 / S212S02
S116S02 / S216S02
Turn-off time
Thermal resistance
(Between junction and case)
S112S01 series
S116S01 series
Thermal resistance ( Between junction and ambience )
Symbol
VF
IR
I DRM
VT
IH
dV/dt
( dV/dt )C
V OX
I FT
R ISO
t on
t off
R th(j - c)
R th(j - a)
Conditions
IF = 20mA
VR = 3V
V D = V DRM
Resistance load
IF = 20mA, IT = 12Arms
Resistance load
IF = 20mA, IT = 16Arms
-
V D = 2/3 • V DRM
T j = 125˚C, VD = 400V, *6
IF = 8mA
VD = 12V, R L= 30
VD = 6V, R L= 30
DC500V, RH = 40 to 60 %
AC 50Hz
AC 50Hz
-
-
-
*6 S112S01 Series: dI T /dt = - 6A/ms
S116S01 Series: dI T /dt = - 8A/ms
MIN.
-
-
-
-
-
-
30
5
-
-
-
1010
-
-
-
-
-
-
TYP.
1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.8
3.3
40
(Ta = 25˚C )
MAX.
1.4
10- 4
10- 4
1.5
1.5
50
-
Unit
V
A
A
V rms
V rms
mA
V/µ s
- V/µ s
35 V
8 mA
8 mA
-
1 ms
10 ms
10 ms
- ˚C/W
- ˚C/W
- ˚C/W


Part Number S116S02
Description (S112S02 / S116S02) SIP Type SSR
Maker Sharp Electrionic
Total Page 5 Pages
PDF Download

S116S02 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 S116S01 SIP Type SSR for Medium Power Control
Sharp Electrionic Components
2 S116S02 (S112S02 / S116S02) SIP Type SSR
Sharp Electrionic





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy