SINAMICS S120 drive system
Booksize format for Line and Motor Modules
Active Line Modules in booksize format
Overview
Design (continued)
The scope of supply of the Active Line Modules includes:
• DRIVE-CLiQ cable for connection to the Control Unit for drive
control on the immediate left
• DRIVE-CLiQ cable (length depends on module width) to
connect Active Line Module to adjacent Motor Module
• 2 blanking plugs for sealing unused DRIVE-CLiQ sockets
• Jumper for connecting the 24 V DC busbar to the adjacent
Motor Module
• 24 V terminal adapter
• Connector X21 for digital inputs
• Fan insert for the 80 kW (100 HP) and 120 kW (150 HP) Active
Line Modules is supplied with the modules. The voltage for the
fan insert is supplied by the Active Line Module.
• 1 set of warning signs in foreign languages
Integration
The self-commutated feed/feedback units (with IGBTs in infeed
and regenerative feedback directions) generate a regulated DC
link voltage. This means that the connected Motor Modules are
decoupled from the line voltage. Line voltage fluctuations within
the permissible supply tolerances have no effect on the motor
voltage. Active Line Modules are designed for connection to
grounded-neutral (TN, TT) and non-grounded (IT) supply
systems.
The Active Line Module communicates via DRIVE-CLiQ with the
CU320 Control Unit, SINUMERIK 802D sl,
SINUMERIK 840D sl with NCU 710.1/NCU 720.2/NCU 730.1/
NCU 730.2 PN or with the Numeric Control
Extensions NX10/NX15 and receives its control information from
these sources.
The DC link is pre-charged via integrated precharging resistors.
In order to operate an Active Line Module, it is absolutely
essential to use the appropriate Active Interface Module or
matching line reactor.
Design
The Active Line Modules in booksize format feature the following
interfaces as standard:
• 1 line connection via screw-type terminals
• 1 connection for the 24 V DC electronics power supply via the
24 V terminal adapter included in the scope of supply
• 1 DC link connection via integrated DC link busbars
• 3 DRIVE-CLiQ sockets
• 2 PE (protective earth) connections
The status of the Active Line Modules is indicated via two
multi-color LEDs.
On the 100 mm (3.94 in) wide Active Line Module, the shield for
the power supply cable can be connected to the integrated
shield connection plate via a shield connection terminal or tube
clip, e.g. Weidmüller type KLBÜ CO 4. The shield connection
terminal must not be used for strain relief. Shield connection
plates are available for the 150 mm (5.91 in), 200 mm (7.87 in)
and 300 mm (11.81 in) wide modules.
The signal cable shield can be connected to the Line Module by
means of a shield connection terminal, e.g. type KLBÜ 3-8 SC
by Weidmüller.
9
Siemens NC 61 · 2007/2008
9/35



Siemens Electronic Components Datasheet

6SL3131-7TE25-5AA3 Datasheet

Active Line Modules in booksize format

No Preview Available !

© Siemens AG 2007
SINAMICS S120 drive system
Booksize format for Line and Motor Modules
Active Line Modules in booksize format
Technical specifications
General technical specifications
Line connection voltage
Up to 2000 m (6562 ft) above sea
level
Line frequency
Power factor
• Active mode
- Fundamental power factor
(cos ϕ1)
- Total (λ)
• Smart mode
- Fundamental mode
- Total
DC link voltage Vd
Electronics power supply
380 ... 480 V 3 AC ± 10%
(-15% < 1 min)
47 … 63 Hz
1.0 (factory setting), can be
altered by input of a reactive
current setpoint
1.0 (factory setting)
> 0.96
0.65 … 0.90
In Active Mode, the DC link
voltage is regulated and can be
adjusted as a voltage decoupled
from the line voltage.
In Smart Mode, the DC link
voltage is regulated in proportion
to the line voltage to the mean
rectified line voltage value.
Factory setting for DC link
voltage:
380 ... 400 V 3 AC: 600 V
(Active Mode)
400 ... 415 V 3 AC: 625 V
(Active Mode)
416 ... 480 V 3 AC: 1.35 x line
voltage (Smart Mode)
24 V DC -15%/+20%
General technical specifications (continued)
Type of cooling
Internal air cooling, power units
with increased air cooling pro-
vided by integrated fan
Built-on fan (with 80 kW (100 HP)
and 120 kW (150 HP) Active Line
Modules).
Permissible ambient or coolant
temperature (air)
in operation for line-side compo-
nents, Line Modules and Motor
Modules
0 ... 40 °C (32 ... 104 °F) without
derating,
> 40 ... 55 °C (104 ... 131 °F),
see derating characteristics
Installation altitude
Up to 1000 m (3281 ft) above
sea level without derating,
> 1000 ... 4000 m (3281 ...
13124 ft) above sea level,
see derating characteristics
Conformity
CE (low-voltage and EMC
directives)
Approvals
cULus (File No.: E192450)
Radio interference suppression
• Active Line Module 16 kW (18 HP)
and 36 kW (40 HP)
- Standard (Active Line Module + no radio interference suppression
line reactor)
- with line filter package
Class A1 to EN 55011 and
Category C2 to EN 61800-3
• Active Line Module
55 kW (60 HP), 80 kW (100 HP)
and 120 kW (150 HP)
- Standard (Active Line Module + Category C3 to EN 61800-3 up to
Active Interface Module)
350 m (1148 ft) total cable length
- with Basic Line Filter
9
Class A1 to EN 55011 and Cate-
gory C2 to EN 61800-3 up to
350 m (1148 ft) total cable length
Category C3 to EN 61800-3 from
350 m to 1000 m (1148 ft to
3281 ft) total cable length
9/36
Siemens NC 61 · 2007/2008


Part Number 6SL3131-7TE25-5AA3
Description Active Line Modules in booksize format
Maker Siemens
PDF Download

6SL3131-7TE25-5AA3 Datasheet PDF






Similar Datasheet

1 6SL3131-7TE25-5AA3 Active Line Modules in booksize format
Siemens





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy