V23042-A2003-B201
V23042-A2003-B201 is Small relay manufactured by Siemens Semiconductor Group.
- Part of the V23042 comparator family.
- Part of the V23042 comparator family.
Features q
Universally applicable in the most varied circuit functions in the field of telemunications and small signal technology Versatile design as it can be delivered with different power consumptions (PN = 150 to 250 m W) as well as with reversed coil polarity High reliability due to slide-free operation of the middle spring High-voltage resistance according to FCC Part 68
Approx. 1.5 x original size q q
ECR0983-1 q
Typical applications q
Versions
- Relay types: monostable with 1 winding or bistable with 2 windings or bistable with 1 winding With 2 changeover contacts With double contacts For printed circuit assembling Immersion cleanable
Standard telemunication relay for public and private networks and terminal equipment Interface relay for microputer systems Storage element for input and output equipment (bistable version) Measurement and control Automobile technology Entertainment electronics Signalling systems Medical equipment q q
- -
- - q q q q q
Approvals
File E 48393
File LR 50227-7
Siemens AG
Free Datasheet http://.datasheet.in/
Small relay D2
Dimension drawing (in mm)
Mounting hole layout
View on the terminals
Monostable and bistable, 1 winding
Bistable, 2 windings
Basic grid 2.54 mm according to EN 60097 and DIN 40803, fine
Basic grid 2.54 mm according to EN 60097 and DIN 40803, fine
Terminal assignment
View on the terminals
Monostable and bistable, 1 winding
V23042-A2III V23042-C2III
Monostable and bistable, 1 winding
V23042-A3III V23042-C3III
Bistable, 2 windings
V23042-B2III
The switch position illustrated shows the release condition. If a positive potential is applied to terminal 1, the relay adopts the operating position.
The switch position illustrated shows the release condition. If a positive potential is applied to terminal 16, the relay adopts the operating position.
The switch position illustrated shows the release condition. If a positive potential is applied to terminal 1 or 15, the relay adopts...