ICP-10125
FEATURES
- Pressure operating range: 30 to 110 k Pa
- Noise and current consumption o 0.4 Pa @ 10.4 µA (ULN mode) o 0.8 Pa @ 5.2 µA (LN mode) o 3.2 Pa @ 1.3 µA (LP mode)
- Pressure Sensor Relative Accuracy: ±1 Pa for any 10 h Pa change over 950 h Pa-1050 h Pa at 25C
- Pressure Sensor Absolute Accuracy: ±1 h Pa over 950 h Pa-1050 h Pa, 0C to 65C
- Pressure Sensor Temperature Coefficient Offset: ±0.5 Pa/C over 25C to 45C at 100 k Pa
- Temperature Sensor Absolute Accuracy: ±0.4C
- IPx8: Waterproof to 10 ATM
- Temperature operating range: -40 °C to 85 °C
- Host Interface: I2C at up to 400 k Hz
- Single Supply voltage: 1.8V ±5%
- Ro HS and Green pliant
TYPICAL OPERATING CIRCUIT
AP/HUB I2C
APPLICATIONS
- Smart watches
- Leisure, Sports, and Fitness Activity Monitoring for
Wearable Sensors
- Altimeters and barometers for portable devices
- Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)
- Home and Building Automation
- Weather Forecasting
Inven Sense, Inc....