GTCX255421M5R02 Gas Discharge Tubes
No Leads: GTCN25-XXXM-R02 Axial Leads: GTCA25-XXXM-R02 Surface-mount: GTCS25-XXXM-R02 Tray / Reel Standard Package 200pcs 5,000pcs 100pcs 1,000pcs 1,500pcs (Reel) 12,000pcs Part Numbering System Example Part Number: GTCX25-351M-R02 GT = C= X= 2= 5= 351 = M= R= 02 = Gas Tube Ceramic Lead Configu.
Gas Discharge Tubes GTCX25-XXXM-R02 Series TE Circuit Protection 5mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that typically result from lightning strikes and equipment switching operations. Raychem Circuit Protection GDTs offer a high level of surge protection, low capacitance and a broad array of breakover voltage le.
GTCX255421M5R02 Features
* 2Pole, 5mm devices
* Broad voltage range from 75V-600V
* Various form factors: surface mount, axial leads, no leads
* Low capacitance and insertion loss
* UL 497B recognized
* RoHS compliant
* Devices tested per ITU K.12 recommendations
* Non-radioactive materials