QPO-1Q sip equivalent, output ripple attenuation sip.
* >20dB PARD attenuation from 50Hz to 500kHz
* Supports point of load regulation
* Peak ripple detector optimizes performance automatically
* Significantl.
(<12V), it may be required to use the CSC capacitor. This creates a soft starting of the source preventing the output fr.
section explains how to optimize the configuration of the QPO-1 for the voltage source used. The headroom voltage is the difference between the input and the output of the QPO-1 and is set by the selection of resistor RHR. Calculate RHR as shown. RHR.